INSTALLATION WITH DIRECT DRAINAGE - RESTORING DRAINAGE INTO THE CONDENSATION
COLLECTION TANK
INSTALLATION WITH DIRECT DRAINAGE
The condensation may be drained directly into an appropriate
drainage point by means of a pipe that is supplied with the unit.
To activate this option proceed as follows:
• remove the rubber cap (8) (Fig.Z1) situated at the side of the
unit and keep it in a safe place;
• open the filter holder grid (3) (Fig.Z1) and slide the condensation
collection tank out (4);
• remove the insert (11) (Fig.Z2) that deactivates the anti-drip
device from the condensation collection tank and keep it in a
safe place;
• insert the pipe (Fig.9) (Fig.Z3) in the joint after having passed it
through the hole, being careful to manually move the anti-drip
device (12)
• re-insert the condensation collection tank (4) (Fig.Z4) and close
the filter holder grid (3)
Warning!
The drainage pipe must slope downwards (Fig.Z6)
and no part of the pipe should exceed the height of the
drainage point on the unit to which it is connected (Fig.Z5);
make sure, on a periodic basis, that the tube is not
obstructed and that it is firmly attached to prevent the
condensation from overflowing.
Z1
8
3
4
Z3
12
9
Z5
Z2
11
Z4
4
Z6
RESTORING DRAINAGE INTO THE
CONDENSATION COLLECTION TANK
To restore drainage into the condensation collection tank,
proceed as follows:
• open the filter holder grid (3) (Fig.Z7) and remove the
condensation collection tank (4);
• carefully slide the tube (9) (Fig. Z8) out of the joint, being careful
to manually move the anti-drip device (12) (Fig.Z8);
• position the insert (11) (Fig.Z9) in the condensation collection
tank (4);
• replace the rubber cap (8) (Fig.Z10) in the casing of the
dehumidifier
• re-insert the condensation collection tank (4) (Fig.Z10) and
close the filter holder grid (3).
Warning!
Remember to reinstall the insert for the de-activation
of the anti-drip device. Water will overflow if this is not re-
inserted.
Z7
3
4
Z9
11
23
Z8
12
9
Z10
4
3
8