BATSI MIE210RPM Manual De Uso página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PULSES PER REVOLUTION (PPR)
The MIE210RPM allows you to set the pulses per revolution you want in each application, from 0
to 20 PPR.
To enter the confi guration menu, follow these steps:
1- Make sure that the controller is disconnected from the power supply.
2- Push and hold the button
3- Connect the controller to power supply again.
Once upon you have confi gured the desired value, disconnect the controller from the power su-
pply and reconnect again for a normal working.
MODIFY SENSOR TYPE
The equipment needs a sensor to count RPM. This sensor can be NPN or PNP type. RPM selector
confi guration:
For PNP type sensor
Put the "RPM" jumper to the P position
5
Press until the desired value appears
For NPN type sensor
Put the "RPM" jumper to the N position