Important Information - Gallagher MR5000 Manual Del Usuario

Ocultar thumbs Ver también para MR5000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
Thank you for purchasing this energizer.
Gallagher, as a world leader in electric fencing, is committed to providing leading products. Gallagher Power
Fences™ are alternatives to traditional barbed and net wire fences at a lower cost. Your new energizer incorporates
the latest in electric fencing technology, ensuring powerful animal control. This energizer has built-in lightning
protection devices to reduce the incidence of lightning damage and built-in RFI (Radio Frequency Interference)
Suppressed Circuitry.
If for any reason you are not happy with your purchase, please return the energizer to your dealer within 30 days of
purchase and we will give you a full refund - guaranteed. If you have any questions regarding this product please
email us: sales@gallagher.co.nz, or contact the store where you purchased this Gallagher product.

IMPORTANT INFORMATION

Warning: Read all instructions
Do NOT touch the fence with the head, mouth, neck or torso. Do not climb over, through or under a multi-wire
electric fence. Use a gate or a specially designed crossing point.
Do NOT become entangled in the fence. Avoid electric fence constructions that are likely to lead to the
entanglement of animals or persons.
Energizer must be installed in a shelter and the supply cord must not be handled when the ambient temperature
in below +5 deg C.
Ensure the Energizer is fully protected from rain, condensation and other sources of moisture.
Do not mount in places exposed to heat sources (e.g. a sun heated metal wall).
Ensure the Energizer has adequate ventilation.
Electric animal fences shall be installed and operated so that they cause no electrical hazard to persons, animals
or their surroundings.
It is recommended that, in all areas where there is a likely presence of unsupervised children who will be
unaware of the dangers of electric fencing, that a suitably rated current limiting device having a resistance of
not less than 500 ohms be connected between the energizer and the electric fence in this area.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Do not place combustible materials near the fence or energizer connections. In times of extreme fire risk,
disconnect energizer.
Regularly inspect the supply cord and energizer for any damage. If found damaged in any way, immediately
cease use of the energizer and return it to a Gallagher Authorised Service Centre for repair in order to avoid a
hazard.
Refer servicing to a Gallagher Authorised Service Centre.
Check your local council for specific regulations.
Energizers with a Standby mode may turn on or off without warning. The energuzer must be disconnected from
the mains supply if it needs to be rendered fully inoperative.
An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits
of the same energizer.
For any two separate electric animal fences, each supplied from a separate energizer independently timed, the
distance between the wires of the two electric animal fences shall be at least 2 m. If this gap is to be closed, this
shall be effected by means of electrically nonconductive material or an isolated metal barrier.
Do not ocnnect two Energiers to the same earth system.
Barbed wire or razor wire shall not be electrified by an energizer.
A non-electrified fence incorporating barbed wire or razor wire may be used to support one or more off-set
electrified wires of an electric animal fence. The supporting devices for the electrified wires shall be constructed
so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the
non-electrified wires. The barbed wire and razor wire shall be earthed at regular intervals.
Follow the energizer manufacturer's recommendations regarding earthing.
The energizer earth electrode should penetrate the ground to a depth of at least 1 m (3 ft) and not be within 10
m (33 ft) of any power, telecommunications or other system.
Use high voltage lead-out cable in buildings to effectively insulate from the earthed structural parts of the
building and where soil could corrode exposed galvanised wire. Do not use household electrical cable.
Connecting leads that are run underground shall be run in conduit of insulating material or else insulated high
voltage lead-out cable shall be used. Care must be taken to avoid damage to the connecting leads due to the
effects of animal hooves or tractor wheels sinking into the ground.
Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables or
data cables.
Connecting leads and electric animal fence wires shall not cross above overhead power or communication lines.
If connected to a mains power circuit that doesn't have a Residual Current Device (RCD), then a plug-in RCD
should always be used.
Important Information
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mr2500

Tabla de contenido