5.2
Data memory progress bar
The data memory progress bar
ity of the DL2 Datalogger.
The data memory progress bar is divided into 10 segments. Each segment repre-
sents 10 % of the memory capacity.
Data memory progress bar
LED segment
permanently on
• The memory capacity of this segment is fully occupied.
flashing
• The memory capacity of this segment is partly occupied.
• VBus
connection okay.
®
5.3
Reset button
The reset button
is integrated in the operating control LED. By means of the
reset button, data logged can be deleted and the DL2 Datalogger configuration can
be reset to the factory settings.
indicates the currently occupied memory capac-
5.4
LAN connector
The integrated LAN connector
The LAN connector supports transfer rates of up to 100 MBits per second.
5.5
SD memory card slot
The SD memory card slot
is located at the left-hand side of the device. By means
of the SD memory card slot, data logged can be transferred onto an SD or SDHC
card of up to 8 GB memory capacity.
The memory of an SD card in the slot is used for data transfer only. It will
not enlarge the memory of the DL2 Datalogger.
5.6
Power supply connection
Power supply is carried out via a pre-connected mains adapter. The connection
terminals are located inside the housing of the DL2 Datalogger.
5.7
RESOL VBus
connection
®
The DL2 Datalogger is to be connected to the controller via the pre-connected
VBus
®
cable. The connection terminals are located inside the housing of the DL2
Datalogger.
is located on the right-hand side of the device.
21