9-23 Parameters for Signals
Matriz [1000]
Solo lectura
Option:
[0]
None
*
6
6
[302]
Minimum Reference
[303]
Maximum Reference
[311]
Jog Speed [Hz]
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[412]
Motor Speed Low Limit [Hz]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out 27 Bus Control
[595]
Pulse Out 29 Bus Control
[615]
Terminal 53 High Ref./Feedb.
Value
[625]
Terminal 54 High Ref./Feedb.
Value
[676]
Terminal 45 Output Bus Control
[696]
Terminal 42 Output Bus Control
[733]
Process PID Proportional Gain
[734]
Process PID Integral Time
[735]
Process PID Differentiation Time
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1500] Operating hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value [%]
[1609] Custom Readout
[1610] Power [kW]
30
PROFINET
Función:
Este parámetro
contiene una lista de
las señales que pueden
seleccionarse en el
parámetro 9-15 Config.
escritura PCD y el
parámetro 9-16 Config.
lectura PCD.
Danfoss A/S © 04/2017 Reservados todos los derechos.
9-23 Parameters for Signals
Matriz [1000]
Solo lectura
Option:
[1611] Power [hp]
[1612] Motor Voltage
[1613] Frequency
[1614] Motor current
[1615] Frequency [%]
[1616] Torque [Nm]
[1617] Speed [RPM]
[1618] Motor Thermal
[1622] Torque [%]
[1630] DC Link Voltage
[1633] Brake Energy /2 min
[1634] Heatsink Temp.
[1635] Inverter Thermal
[1638] SL Controller State
[1639] Control Card Temp.
[1650] External Reference
[1652] Feedback[Unit]
[1653] Digi Pot Reference
[1657] Feedback [RPM]
[1660] Digital Input
[1661] Terminal 53 Setting
[1662] Analog input 53
[1663] Terminal 54 Setting
[1664] Analog input 54
[1665] Analog output 42 [mA]
[1667] Pulse input 29 [Hz]
[1668] Pulse input 33 [Hz]
[1669] Pulse output 27 [Hz]
[1670] Pulse output 29 [Hz]
[1671] Relay output
[1672] Counter A
[1673] Counter B
[1679] Analog output 45 [mA]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1684] Comm. Option STW
[1685] FC Port CTW 1
[1690] Alarm Word
[1691] Alarm Word 2
[1692] Warning Word
[1693] Warning Word 2
[1694] Ext. Status Word
[1695] Ext. Status Word 2
[1697] Alarm Word 3
[3401] PCD 1 Write For Application
[3402] PCD 2 Write For Application
[3403] PCD 3 Write For Application
[3404] PCD 4 Write For Application
[3405] PCD 5 Write For Application
[3406] PCD 6 Write For Application
Función:
MG06G105