• Do not attempt to connect or set up the inverter or its components while operating your vehicle. Not paying attention to the road may
result in a serious accident.
• Always use the inverter where there is adequate ventilation. Do not block ventilation slots.
• Always turn the inverter off by disconnecting it from the power source when not in use.
• Make sure the nominal powering voltage is 12 volts DC, center connection positive (+).
• Do not use with positive ground electrical systems.* Reverse polarity connection will result in a blown fuse and may cause permanent
damage to the inverter and will void warranty.
*The majority of modern automobiles, RVs and trucks are negative ground.
• Keep in mind that this inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, microwave
ovens and toasters.
• Do not open the inverter — there are no user-serviceable parts inside. Opening the inverter will void manufacturer's warranty.
• Do not use this inverter with medical devices. It is not tested for medical applications.
• Install and operate inverter only as described in this Instruction Manual.
SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: Follow these instructions and those published by the
manufacturer of any equipment you intend to use with this inverter. Review cautionary markings on these products.
INTRODUCTION
Congratulations on purchasing your new
Stanley
Fatmax
®
instructions carefully before using your new inverter.
This power inverter is configured to supply continuous power in the form of two 120 volt AC outlets and one 5 volt USB charging port to
run most household or electronic appliances.
HOW THIS INVERTER WORKS
This inverter is an electronic device that converts low voltage DC (direct current) electricity from a battery to 120 volts AC (alternating
current) household power. It converts power in two stages. The first stage is a DC-to-DC conversion process that raises the low voltage
DC at the inverter input to 145 volts DC. The second stage is a MOSFET bridge stage that converts the high voltage DC into 120 volts,
60 Hz AC.
Power Inverter Output Waveform
The AC output waveform of this inverter is known as a modified sine wave. It is a stepped waveform that has characteristics similar to the
sine wave shape of utility power. This type of waveform is suitable for most AC loads, including linear and switching power supplies used
in electronic equipment, transformers, and small motors.
CAUTION: Rechargeable Devices
• Certain rechargeable devices are designed to be charged by plugging them directly into an AC receptacle. These devices may damage
the inverter or the charging circuit.
• When using a rechargeable device, monitor its temperature for the initial ten minutes of use to determine if it produces excessive heat.
• If excessive heat is produced, this indicates the device should not be used with this inverter.
• This problem does not occur with most of the battery-operated equipment. Most of these devices use a separate charger or transformer
that is plugged into an AC receptacle.
• The inverter is capable of running most chargers and transformers.
PROTECTIVE FEATURES
The inverter monitors the following conditions:
Input Voltage Too Low: This condition is not harmful to the inverter, but could damage the power source, so the inverter will
automatically shut down when input voltage drops below 10.5 ± 0.5 volts DC.
Input Voltage Too High: The inverter will automatically shut down when DC input voltage exceeds 16 ± 0.5 volts, as this can harm the
unit.
Thermal Shutdown Protection: The inverter will automatically shut down when the unit becomes overheated.
Overload/Short Circuit Protection: The inverter will automatically shut down when an overload or short circuit occurs.
Note:
The Power/Fault LED Indicator will light red to indicate an input voltage too low, input voltage too high or thermal fault condition OR flash red and
blue to indicate an overload or short circuit fault condition before automatic shutdown occurs.
RATED VERSUS ACTUAL CURRENT DRAW OF EQUIPMENT
Most electrical tools, appliances, electronic devices and audio/visual equipment have labels that indicate the power consumption in amps
or watts. Be sure that the power consumption of the item to be operated is below 140 watts for 20 minutes, 120 watts for 60 minutes and
100 watts continuous or the unit may overheat and shut down. If the power consumption is rated in amps AC, simply multiply by the AC
volts (120) to determine the wattage.
Resistive loads are the easiest for the inverter to run; however, it will not run larger resistive loads (such as electric stoves and heaters),
which require far more wattage than the inverter can deliver. Inductive loads (such as TVs and stereos) require more current to operate
than do resistive loads of the same wattage rating.
PCI140_ManualENSP_061714.indd 4-5
. Read this Instruction Manual and follow the
140 Watt Power Inverter
®
4
For safety reasons, the inverter will simply shut down if it is overloaded. To restart the unit, simply unplug all devices plugged into the
inverter; disconnect the inverter from any 12 volt DC power source; then reconnect the inverter BEFORE plugging the appliance(s) back in.
OPERATING INSTRUCTIONS
The power/fault LED indicator lights blue when the inverter is properly connected to a functioning DC power source and the on/off button
is pressed to turn the unit on. The AC and USB outlets are ready to use. (If the power/fault LED indicator lights red or flashes red and blue,
refer to the Troubleshooting Section of this Instruction Manual.)
To turn the unit off, press the on/off button to turn the unit off, then disconnect it from the 12 volt DC power source.
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:
• The Power Inverter must be connected only to batteries with a nominal output voltage of 12 volts. The unit will not
operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery.
• Always connect the inverter to the 12 volt DC power source before plugging any devices into the unit.
• The standard North American 120 volt AC and USB outlets allow simultaneous operation of multiple devices. Simply plug the equipment
into the unit and operate normally.
Note:
Ensure that the wattage of all equipment simultaneously plugged into the inverter does not exceed 140 watts for 20 minutes, 120 watts for 60
minutes and 100 watts continuous or the unit may overheat and shut down.
Operation of the 120 Volt AC Outlets and USB Power Port
1. Connect the unit's 12VDC accessory plug to a vehicle's accessory outlet or other 12 volt DC power source. Make sure there is adequate
space for proper ventilation of the inverter.
2. Rotate the plug slightly to make sure there is good contact.
3. Press the on/off button to turn the inverter on.
3. The bi-color power/fault LED indicator will light blue, indicating a proper connection. If the bi-color power/fault LED indicator lights
red or flashes red and blue, a fault condition exists. Refer to the Troubleshooting Section of this Instruction Manual.
4. Plug the (110/120 volt AC) appliance into the inverter's three-prong AC outlets and/or plug the USB-powered device into the inverter's
USB Charging Port and operate normally.
Notes:
If the inverter does not work, make sure the ignition/accessory switch is actually powering the accessory outlet. Some vehicles require the ignition
switch to be turned on.
Some laptop computers may not operate with this inverter.
The inverter will not operate appliances and equipment that generate heat, such as hair dryers, electric blankets, microwave ovens and toasters.
This inverter's USB charging port does not support data communication. It only provides 5 volts/1,000 mA DC power to an external USB-powered
device.
Some USB-powered household electronics may not operate with this USB charging/power port. Check the manual of the corresponding electronic
device to confirm that it can be used with this type of USB charging/power port.
Remember to disconnect the unit from any power source when it is not in use.
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE: Remember to turn the inverter off and disconnect it from any power source
when it is not in use. Also remember to turn off the accessory outlet switch to avoid draining's the vehicle's battery.
Mounting the unit by Mounting Clip
The unit can be mounted can be mounted on any flat, secure surface, especially inside the vehicle, by installing the mounting clip located
at the back of unit.
1. Press the mounting clip release button at the top of unit and simultaneously slide the mounting clip off the back of the inverter.
2. Mount the mounting clip with two supplied KA3x10 screws or the two supplied pieces of double-sided tape on any flat, secure
surface.
3. To attach the inverter to the mounting clip, slide the unit into the mounting clip until you hear a "click" indicating the unit is secured
in place.
4. To detach the unit, press and hold the mounting clip release button on the top of unit and gently slide it off the mounting clip.
CAUTION: To reduce the risk of product damage:
• Only use the mounting clip for mounting the inverter. The mounting clip is not intended to support additional weight. Do not attach to
or hang anything from the mounted inverter.
• When disconnecting an appliance from the mounted inverter, use one hand to hold the mounted inverter in place and gently unplug
the appliance with the other hand. Otherwise, the inverter could be unseated from the mounting and fall.
• Always press and hold the mounting clip release button to gently slide the inverter off the mounting clip. Attempting to slide the
inverter without holding the mounting clip release button or forcing the inverter in any way could damage the locking mechanism.
Operating Tips
The inverter should only be operated in locations that are:
DRY — Do not allow water or other liquids to come into contact with the inverter.
COOL — Surrounding air temperature should ideally be 10-20°C (50-68°F). Keep the inverter away from direct sunlight, when possible.
WELL-VENTILATED — Keep the area surrounding the inverter clear to ensure free air circulation around the unit. Do not place items
on or over the inverter during operation. The unit will shut down if the internal temperature gets too hot. The inverter will auto-reset
after it cools down.
5