 Needle Kits and Air Line Adapters – check Disposable
Dispense Components listing at
www.equipment.loctite.com
9
I/O Configuration & Pneumatic Diagram
Upon completion of a dispense cycle, an open collector circuit
closes and remains closed until the next dispense cycle. This
circuit can be used to signal back to a host computer, start
another device in sequence, or drive any other operations that
need to be tied to the completion of the dispense cycle. Upon
closure, (end of dispense cycle), power from an external source
is allowed to pass through the circuit to operate a 5 to 24 VDC
load. Power consumption must not exceed 250 mA. The load
could be a relay, solenoid, counter, LED, or any device that will
operate within a 5 to 24 VDC range and a maximum of 250 mA.
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 5
Pin 7, 8 and 9 = available
Pneumatic Diagram
To initiate a d
ispense cycle
During cycle =
End of cycle =
During cycle =
End of cycle =
OPEN
To initiate a d
ispense cycle
with contact closure
Chasis Ground
AIR INLET
NEEDLE VALVE
AIR OUTLET
12
GROUND
OPEN
GROUND
AIR MANIFOLD
3
2
1
SOLENOID VALVE
PRESSURE REGULATOR