Operation
Start and stop (on standard integrated control boxes)
Th e unit can be started and stopped manually by push but-
tons on the box. After such start the unit will work for a
max of 2 hours and then it will stop automatically. Th e max
runtime can be adjusted, see below.
When the work area/vacuum point is equipped with a micro
switch/pressostat you also have the facility for remote on/
off within the panel. When no outlet is open the machine
continue to work for 5 mins, then shut down. Th e time can
be adjusted, see below.
Operation DC Green System
Start and stop
Unit is started and stopped manually on display, see be-
low: As an alternative to manual start can withdrawals be
equipped with micro switches / pressure switches. When
no longer socket is open, the unit continues to move in
5 minutes, then turn off . Th e delay can be adjusted, see
below.
Th e system can also be confi gured for clock control. Th is
means that the start and stop controlled by a program-
med clock. It is common that the operation follows the
shifts, where the plant turns the fi lter cleans during
breaks. Setting the clock, see below.
Operation
Filter cleaning (manual)
Th e fi lter should be cleaned 1-2 times per day when running
continuously.
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
Emptying separated material
All separated material is collected under the cyclone in a
plastic sack or container.
Th e plastic sack should be changed when the dust level is
about 5 cm under the outlet fl ap. Th e plastic sack must
be sealed after is has been taken off the machine. Use only
original plastic sacks.
Th e unit can also be confi gured for clock control; start/stop
is controlled by a programmed clock. Usually the unit would
be set to run in accordance with shifts then close down and
fi lter clean during rest periods. To adjust the clock, see below.
Filter cleaning (automatic)
After system shutdown the fi lter is cleaned by air pulse over
a 4 minute period. You can hear the air pulses like strong
punches inside the fi lter unit approximately every 20 seconds.
Th e times for fi lter cleaning can be adjusted, see below. Also
automatic fi lter cleaning during operation can be specifi ed
for some installations. You can also manually start the fi lter
cleaning via a button on the control box.
Note that if you have a suction equipment that is less
than 38, the fl ap should be kept open for a little while
before you connect the hose to the system to change up
to the control mode. In any case where the equipment has
very small dimensions may be forced to slangmuff en or
tubing to make a hole to let in extra air. Th e hole should
be 15 to 20 mm.
Th e system can also be confi gured for fi lter cleaning
during operation. In this case, cleaned the fi lters about 1
times per hour when the system is in sleep mode
Th e container should be emptied when it is fi lled to ca 3/4.
Some containers have a sight glass so the fi lllevel can be
viewed from the outside. When emptying the container you
normally should put a trolley or moveable load bearing item
under the container before the eccentric lock is released.
Alarm
When the alarm lamp is on the motor protection has trip-
ped. Th e fault should be investigated and attended before the
motor protection is restored and the system can be started
once again.
DC 11-Module - 33
Part No 94153-D