Installation Guide
Installer setup
Setup functions
0300
Manual/Auto
changeover
0320
Temperature
display
0340
Remote Temperature
Sensor
0345
Dual Fuel Heat Pump
Control
0346
Dual Fuel Heat Pump
Upstage to Furnace
Timer
0347
Drop Temperature
0350
HP Compressor
Lockout also Balance
Point
P/N 041-338 Rev. C
Settings & Options
1
Automatic changeover (Heat/Cool/Auto/OFF)
0
Manual changeover (Heat/Cool/OFF)
0
Fahrenheit ( ºF)
1
Celsius ( ºC)
0
None
1
Outdoor for Display
2
Outdoor for Control
3
Remote Indoor
0
Balance point only
1
Balance point + Failed to Maintain Heat protection
2
Low lockout + High Lockout + Failed to Maintain protection
in between.
0
Disabled
0.5 0.5 hours
1
1 hour
1.5 1.5 hours
2
2 hours
3
3 hours
4
4 hours
5
5 hours
6
6 hours
8
8 hours
10 10 hours
12 12 hours
14 14 hours
16 16 hours
2
2 ºF
1.0 ºC
3
3 ºF
1.5 ºC
4
4 ºF
2.0 ºC
5
5 ºF
2.5 ºC
40 40 ºF 4.5 ºC
0
None
5
5 ºF
-15.0 ºC
10 10 ºF -12.0 ºC
15 15 ºF -9.5 ºC
20 20 ºF -6.5 ºC
25 25 ºF -4.0 ºC
30 30 ºF -1.0 ºC
35 35 ºF 1.5 ºC
45 45 ºF 7.0 ºC
50 50 ºF 10.0 ºC
55 55 ºF 13.0 ºC
60 60 ºF 15.5 ºC
8
(factory default in bold)
Continued on next page
69-2655EFS—05