Either hold
pressed for at least 5 seconds or leave the device inactive for more than 30 seconds to quit
programming mode.
The red button
turns blue, the device will generate a long confi rmation beep and then return to normal
operation.
TIMESLOT TERMINAL PROGRAMMING PROCEDURE
By enabling the "time slot" function, a timer (not included) may be used to defi ne the times of the day when
to activate one of the two relays simply by pressing the
Access programming mode.
Enter confi guration code 40 a where:
40 identifi es the programming function code
a
defi nes the number of relays enabled during the timeslots.
1 = relay 1
2 = relay 2
0 = function off
Press
to confi rm.
The device generates 3 confi rmation beeps and the button
If the entered code is wrong, the device will generate one long beep and wait for the correct code to be
entered.
Either hold
pressed for at least 5 seconds or leave the device inactive for more than 30 seconds to quit
programming mode.
The red button
turns blue, the device will generate a long confi rmation beep and then return to normal
operation.
DEVICE RESET (TO RESTORE DEFAULT SETTINGS)
Disconnect power from the device.
Hold the programming switch (SW1) pressed.
Power the device while the SW1 switch is pressed. A long beep will be heard.
Release the switch after 5 seconds.
The device will beep 3 times for confi rmation when the switch is released.
All the previously programmed codes, times and passwords will be deleted.
DEFAULT SETTINGS
Relay 1
Function
Activation time
Button confi rmation
Relay 2
Function
Activation time
Button confi rmation
Timeslot terminal
Operating mode jumper: 2Voice and Ipercom systems
MAINTENANCE
Use a soft damp cloth to clean the front panels. Do not use products containing alcohol or window cleaning
products.
12
Monostable
200 ms
No
Monostable
200 ms
No
OFF
button.
turns from red to blue to red.