Installation
The CDFI1000-PRO and
CDFI500-PRO are supplied in an
assembled state and are designed
to be permanently installed. The
units come ready for hardwire
installation and the use of the
water refill containers.
WARNING: Construction and
electrical outlet wiring must
comply with local building codes
Product Dimensions
CDFI500-PRO
CDFI500P
20.04 in. (509 mm)
20.04 in. (509 mm)
CDFI1000-PRO
CDFI1000P
6
Media Plate: 11.94 in. (303 mm)
Logset: 13.94 in. (353 mm)
40.08 in. (1018 mm)
40.08 in. (1018 mm)
and other applicable regulations
to reduce the risk of fire, electric
shock and injury to persons.
WARNING: To reduce the risk of
fire, do not store or use gasoline
or other flammable vapours or
liquids in the vicinity of the unit.
!
NOTE: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essential
in all cases. A dedicated circuit will
be required if, after installation,
the circuit breaker trips or the fuse
blows on a regular basis when the
cassette is operating. Additional
appliances on the same circuit may
exceed the current rating of the
circuit breaker.
Adjustable from
9.13 in. (232 mm)
to 9.63 in. (245 mm)
!
NOTE: When prepar-
ing the opening for the unit
¼ in. (6.4 mm) of clearance
should be maintained from
each surface to ensure easy
installation.
Media Plate: 11.94 in. (303 mm)
Logset: 13.94 in. (353 mm)
Adjustable from
9.13 in. (232 mm)
to 9.63 in. (245 mm)
www.dimplex.com