Table 2: CFW500-ENC2 signals from the control
Connector
1
DO1-NO
3
DO1-C
5
D03-NO
7
DO3-C
9
DO4-NO
11
DO4-C
13
GND
15
DI6
17
DI7
19
DO2
21
+24 V
23
+VE
2
DI1
4
DI2
6
DI3
8
DI4
10
DI5
12
RS-485 - A RS-485 (Terminal A)
14
RS-485 - B RS-485 (Terminal B)
16
GND
18
A
20
/A
22
B
24
/B
ENC Encoder Input Plug-in Module
connections
Description
Digital output 1
(NO contact of relay 1)
Digital output 1
(common point of relay 1)
Digital output 3
(NO contact of relay 3)
Digital output 3
common point of relay 3)
Digital output 4
(NO contact of relay 4)
Digital output 4
(common point of relay 4)
Reference 0 V
Digital input 6
Digital input 7
Digital output 2 ( Transistor)
24 Vdc Power supply (Transistor)
Output Power Supply +12 V
S2.1 = OFF) or +5 V (S2.1 = ON)
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5 (NPN only)
Reference 0 V
Non-inverting quadrature input A
Inverting quadrature input A
Non-inverting quadrature input B
Inverting quadrature input B
CFW500 | 9