only for qualified personnel
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply
cables apart (minimum 4 mm in the air or 1 mm through insulation) from low voltage cables (motors
power supply, controls, aerial and auxiliary circuits power supply) and fasten the latter with appropriate
clamps near the terminal boards .
WARNING The device shouldn't be used by children and/or persons with reduced capacities (physi-
cal, sensorial, mental). Prevent children from playing with the device. All these operations must be per-
formed only after disconnecting the power supply and operating in strict compliance with the electrical
standards and regulations in force in the nation of installation.
WARNING For further details and control board installation and wire make reference to the instruc-
tions given (such as hole drilling to allow for wires passage, use of wire clamps..). Failure to comply with
these instructions may jeopardize the level of electrical safety.
WARNING The 212E control panel hasn't any internal devices for the protection of mechanical risks
following to the gate/door movement (es: limitation of impact forces). If such risks are founded, external
protection devices (independent from the control panel) are necessary. An erroneous evaluation of im-
pact forces may cause serious damages to persons, animals, things. DEA System reminds the installer
to check these impact forces, measured following the EN 12445 standard. Such impact forces must be
lower than what foreseen from the EN 12453.
WARNING Other eventual protection devices to respect the impact forces must be in conformity with
EN 12978 standard.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assembly may en-
danger people, animals and property, and may also cause malfunctioning of the products: always use
parts provided by DEA System and follow assembly instructions.
WARNING Disposal of packing materials (such as plastic, card board, etc..) must be done ac-
cording to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of
children.

3 MODELS AND CONTENTS OF THE PACKAGE

The 212 E control board is supplied in a box which permits the external assembly with IP 55 protection
degree. It may also be installed in automatism which permits the electronics on board.

4 PRODUCT DESCRIPTION

The 212 E control board was studied exclusively to control DEA SYSTEM automations, with 1 or 2 230 V ~
motors; therefore it is used for automate sliding, sectional and wing gates. Main features of the product:
• easy installation;
• setting all parameters by 2 keys and led signalling;
• built-in 433.92 MHz radio receiver for both HCS and HT12E coding.

5 TECHNICAL DATA

8
Power supply ....................................................230 V ~ - 50Hz
Flashing light output .........................................230 V ~ max 40W art. Lumy
Auxiliary power supply output (+24VAUX) ..........24 V ~
Safety devices power supply output (+24VSIC) ...24 V ~
Max motor capacity ..........................................2 X 500W max
Fuse F1 ............................................................T5A
Fuse F2 ............................................................T100mA
Radio receiver frequency ...................................433,92 MHz rolling code/dipswitch code
Max. number of radio controls managed ...........30
Protection level
..............................................IP 55 (box)
}
Max 200mA
250V retarded
250V retarded
A4
A5
A6
A9
A10
A11