TO CHANGE OPERATING MODES:
Disconnect air line from tool and remove fasteners from magazine before making
adjustments or personal injury may result.
Always know the tool operating mode before connecting to an air supply and/or using the
tool.
SEQUENTIAL TRIP-
1. Push and hold in pivot pin opposite the selector, while rotating the selector 180° counterclockwise to the
sequential trip position
2. Ensure the selector is fully seated in the new position.
To operate the nailer in sequential trip mode:
1. Depress the contact trip firmly against the work surface.
2. Depress the trigger.
A nail will fire each time the trigger is depressed as long as the contact trip remains
depressed.
CONTACT TRIP -
1. Push and hold in pivot pin while rotating the selector 180° clockwise to the contact trip position
2. Ensure the selector is fully seated in the new position.
To operate the nailer in contact trip mode:
1. Depress the trigger.
2. Push the contact trip against the work surface. As long as the trigger is depressed, the tool will fire a nail
every time the contact trip is depressed. This allows the user to drive multiple nails in sequence.
Do not keep trigger depressed when tool is not in use.
AIR SUPPLY AND CONNECTIONS
Do not use oxygen, combustible gases, or bottled gases as a power source for this
tool as tool may explode, possibly causing injury.
Do not connect tool to any air supply which could potentially exceed
200 p.s.i.g. (14 kg/ cm
FITTINGS:
Install a male plug on the tool which is free flowing and which will release air pressure from the tool when
disconnected from the supply source.
HOSES:
Air hoses should have a minimum of 150 p.s.i. (10.5 kg/cm
maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will
provide "quick disconnecting" from the male plug on the tool.
SUPPLY SOURCE:
Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN,
COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL
MAY EXPLODE.
.
Pivot Pin
Selector
) .
2
-6-
) working pressure rating or 150 percent of the
2
.