SPECIAL CONDITONS FOR SAFE USE
ATEX/IECEx
• The equipment shall only be used in areas with a low risk of mechanical impact.
• Electrical connections to the equipment are not permitted in the hazardous area.
• The model 'Tab-Ex 02 DZ1 WWAN' shall only be opened for SIM Card access in
the non-hazardous area as per Pepperl+Fuchs guidance document DOCT-6352.
All other equipment models shall not be opened by the end user for any reason;
if either of the equipment's enclosures are opened or damaged, the following
conditions shall apply:
• The equipment must be removed from the explosive atmosphere immediately and
will not be suitable for re-use until it is repaired by the OEM.
• If the outer enclosure is damaged precautions shall be taken to ensure the inter-
nal flameproof enclosure is not subject to static charging.
• If the inner flameproof enclosure is opened, the equipment must never be used in
an explosive atmosphere unless it has been repaired and re-sealed by the OEM.
Mining
• The equipment shall only be used in areas with low risk of mechanical impact.
• Electrical connections to the equipment are not permitted in the hazardous area.
• The product shall not be used where chemical agents such as oil or grease
are likely to come into contact with the equipment. This requirement shall be
in accordance with EN IEC 60079-0: 2018, Clause 26.11 / IEC 60079-0: 2017,
Clause 26.11.
• The model 'Tab-Ex 02 DZ1 WWAN' shall only be opened for SIM Card access
in the non-hazardous area as per the ecom Pepperl and Fuch's guidance
document DOCT-6352. All other equipment models shall not be opened by the
end user for any reason; if either of the equipment's enclosures are opened or
damaged, the following conditions shall apply:
• The equipment must be removed from the explosive atmosphere immediately
and will not be suitable for re-use until it is repaired by the OEM.
• If the outer enclosure is damaged precautions shall be taken to ensure the
internal flameproof enclosure is not subject to static charging.
• If the inner flameproof enclosure is opened, the equipment must never be
used in an explosive atmosphere unless it has been repaired and re-sealed by
the OEM.