Descargar Imprimir esta página

Mosquito Magnet PATRIOT PLUS Manual De Operación página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Easy Quick Clear Valve
Important: Extinguish all smoking materials prior
to use of Easy Quick Clear Valve. Do not stand directly
behind the Quick Clear cartridge during operation.
Use of PROTECTIVE eyewear is recommended.
Quick Clear is recommended for regular maintenance to
remove built-up contaminants.
Recommended for use at every tank change. Also
recommended for use before seasonal storage to avoid build
up of contaminants during the off-season. Instructions for
"Easy Quick Clear Valve" maintenance procedure shall be
provided on a label attached to trap where easily visible by user.
The Easy Quick Clear Valve is a threaded knob located on
the back of your trap. It should be used with the adapter
included with your trap, and a threaded Quick Clear cartridge
available on our website at: www.mosquitomagnet.com
or at your local hardware or home improvement store.
1. Important:
Shut down your trap. Let fan run until it stops.
(About 5 minutes.)
2. Close the propane tank valve by turning to the "OFF"
position. (Turn the tank valve clockwise.)
3. Remove the protective cap from Easy Quick Clear
valve located in the back of the trap.
4. Hand-screw the Quick Clear adapter on to Quick Clear
valve, until finger tight.
5. Hand-screw the Quick Clear cartridge into the Quick
Clear adapter clockwise until hand tight while holding
the adapter in place. Important: Do not over-tighten.
6. While holding the adapter in place slowly unscrew
Quick Clear cartridge up to 1/4 turn only in counterclockwise
direction from the Quick Clear adapter only. The strong flow of
compressed air lasts approximately 45 seconds. Be sure to
allow Quick Clear cartridge to run out completely. (Hissing will
stop when cylinder is empty. Quick Clear cartridge will be cold
to the touch.)
7. Unscrew the Quick Clear cartridge to remove. Discard empty
Quick Clear cartridge after use, it is not reusable or refillable.
8. Unscrew the Quick Clear adapter to remove.
Use caution when removing Quick Clear adapter and cartridge,
as some compressed air may come out at this time.
Remember to keep the Quick Clear adapter for future use.
9. Replace Easy Quick Clear Valve protective cap, and
proceed with normal start up of your trap. If use of Easy
Quick Clear valve feature does not resolve startin
trouble, contact Customer Care 1-800-953-5737.
13
Step 4
First hand-screw the Quick Clear adapter onto the valve.
Step 5
While holding the adapter in place, screw the Quick Clear
cartridge into Quick Clear adapter.
Step 6
To start cleaning process, while holding Quick Clear Adapter
in place, unscrew the Quick Clear cartridge 1/4 Turn Only.
Step 7
Unscrew the Quick Clear cartridge first, then unscrew Quick
Clear adapter and discard the spent Quick Clear cartridge.
Remember to keep the Quick Clear adapter for future use.
Troubleshooting
Problem
Possible Cause
1. Is the propane tank empty?
2. If propane tank is new, it may have
air blockage, has it been purged?
3. If tank has been opened too quickly, security
Your Mosquito Magnet
®
check valve may have triggered.
won't start
4. Is the power cord plugged in?
5. Is there a loose connection?
6. The outdoor temperature is below 50˚F (10˚C).
7. The tank regulator isn't fully engaged.
8. Propane tank may be empty or need to be
purged.
Your Mosquito Magnet
®
won't start
9. Regulator is not fully engaged
10. Fuel line may be blocked by propane
contaminants.
11. Insects may not be out yet.
12. Trap improperly placed.
Low or no catch
13. Biting insects reproductive cycles have not
yet been broken.
Customer Care **Please have your serial number, date of purchase & model type available**
All of us at Woodstream
Corporation want you to get complete satisfaction from your trap. Should you have any problems you cannot
®
resolve, simply call one of our trained Customer Service Representatives at 1-800-953-5737 or visit www.mosquitomagnet.com.
We will help you get up and running.
Solutions
1. Weigh tank and check against "empty" weight
written on tank.
2. Bring tank to filling location. Air may be in
fuel line. Ask for tank to be purged.
Hint: If you have another propane powered
device operating on a standard, 20 lb propane
tank, try hooking that tank up to the trap to
verify that the issue is with your tank.
3. Disconnect the regulator from the tank and
reconnect. Then open the regulator valve slowly.
4. Verify all electrical connections. Make sure you are
using the correct power requirements for your unit.
5. Make sure regulator is fully engaged, and propane
tank valve is fully open.
6. Mosquitoes are not active at this climate; wait
until the temperature is consistently above 50° F
(10˚C) before starting your trap.
7. Make sure the regulator is fully engaged, and
propane tank valve is fully open.
8. Go through above steps 1, 2 and 3.
9. See tank changing tips on page 12. Hand
tighten the propane tank regulator until
slightly snug.
10. Follow Easy Quick Clear Valve instructions.
See page 13.
11. Verify temperature is consistently above 50˚F (10˚C).
12. Follow steps in the "Trap Placement" section of
your owner's manual or go to
www.mosquitomagnet.com "Placement" section.
13. Keep trap in constant operation 24 hours/day,
7 days/week for 4 weeks to interrupt the
breeding cycle.
14