PACKING CONTENTS:
A. Opaque hose for connecting the pump's outlet to the
injection point
B. Transparent hose for suction and for connecting the
bleeding valve up for manual priming
C. Injection fitting
D. Hose connection kit
E. Bottom filter
F. Wall mounting bracket
G. Anchors for securing the pump to the wall
H. Screw protection caps
I.
Instructions Manual
Below are the technical and pump performance data:
Model
200
INTRODUCTION
The pump is composed of a part that houses the control electronics and the magnet and a hydraulic side always in contact with
the liquid to be dosed.
Check the rating plate of the main features of your pump
155
1
2
We recommend checking the chemical compatibility between the product and the materials in contact.
PUMP HEAD MATERIALS
Pump body:
•
Valves:
•
Balls:
•
Diaphragm:
•
EM00136319
INSTALLATION AND START-UP MANUAL
FOR OPTIMA MAN NEXT DOSING PUMP
PVDF-T
Pressure Flow rate
bar
l/h
8
5
10
3
3
191
271
PVDF-T
PVDF-T
Ceramic
PTFE
rev.2.0
A
E
Connections
cc /stroke
(mm)
Int / Ext
0.52
4 / 6
0.31
4
131
5
6
EN
C
B
D
F
G
H
stroke /
min
160
1 Adjustments area
2 Dosing head
3 Priming valve
4 Delivery connector
5 Suction connector
6 Base fixing bracket (optional)
I
1