Direction Of Rotation - Campbell Hausfeld CE9002 Instrucciones De Funcionamiento Y Manual De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS (CONTINUED)

Direction of Rotation

NOTE: Improper rotation will result in reduced compressor
life.
The direction of rotation must be counterclockwise (as
shown by the arrow on the flywheel in Figure 7) while facing
the flywheel side of the pump. The motor nameplate will
show wiring information for counterclockwise rotation.
The proper direction is very important. The direction of
rotation of 3 phase motors can be reversed by interchanging
any two motor-line leads. For single phase motors, refer to
the motor nameplate.
Lubrication
This unit contains no oil.
Before operating compressor, fill
to the center of the sight gauge (see Figure 8).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Part number ST125303AV (0.5 qt) or
ST126701AV (4 qt).
10W30 synthetic oil such as Mobil 1
Oil Capacity
Approximately 6 quarts
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 8).
through the breather cap opening as this may cause oil
to leak and spray out during operation.
NOTE: Some residual oil may still be in the pump from factory
testing leaving a thin coat on the sight gauge; however, there is
not enough oil to operate the unit.
Figure 7 - Direction of rotation
or CE0032 (1 qt).
®
Do NOT fill the pump
Figure 8
Full
Low
Sight Gauge
Breather Cap
and Oil Fill Port
Oil Drain Plug
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ce9002fpCe9004Ce9004fpCe9005Ce9005fp

Tabla de contenido