Enrolling the Keypad
The WT5500 must be configured in tandem with your panel in order for the
system to function as desired.
1. Apply power to the control panel. Keypad enrollment is active during the
first two minutes of system power up. Note that the panel's Ready and
AC LEDs will be flashing for this two-minute period.
2. A WT5500 must be turned on during this two-minute period for it to be
assigned to the panel.
,
3. Simultaneously press and hold [
] and [1]; by doing so you force the
keypad to broadcast its ESN (Electronic Serial Number).
4. When the keypad has been successfully enrolled on the system (this
should take less than 5 seconds), the message 'Enrollment Successful'
will be displayed on the keypad LCD for five seconds. The Ready and AC
LEDs will return to their previous state.
5. Repeat steps 3 & 4 on each additional keypad to be enrolled (PC9155 only).
NOTE: Only one WT5500 can be enrolled with the SCW9055/9057.
Changing Brightness/Contrast
,
1. Press [
][6][Master Code].
2. Use the arrow keys (<>) to scroll to Brightness or Contrast Control.
,
3. Press [
] to select the setting you want to adjust.
4. Brightness Control: There are multiple backlight levels. Use the arrow
keys (<>) to scroll to the desired level. Press [
5. Contrast Control: There are four different display contrast levels. Use the arrow
keys (<>) to scroll to the desired contrast level. Press [
6. To exit, press [#].
NOTE: During battery operation, the keypad uses the ambient light sen-
sor
to automatically adjust the backlighting brightness levels in
order to conserve battery life.
Changing the Buzzer Level
,
1. Press [
][6] [Master Code].
2. Use the arrow keys (<>) to scroll to Buzzer Control. Press [
3. Use the arrow keys (<>) to scroll to the desired buzzer level among
the 21 available selections.
4. To exit, press [#].
Keypad LED Symbols
Symbol
Ready Light (Green)
Armed Light (Red)
System Trouble (Yellow)
AC (Green)
Proximity Tags (WT5500P only)
Prox Tag
Reader
You can use the proximity tag to perform any keypad function that would nor-
mally require a user access code. Simply present the tag to the target icon or
to the left of the keypad LCD.
Enrolling Proximity Tags
Enrolling a tag on one keypad will enroll it automatically to all WT5500P
keypads enrolled on the system.
,
] to select.
,
][5][Master Code]. You will enter the User Code Edit Select
1. Enter [
menu.
,
] to select.
2. Enter a two-digit User Code slot (01-16, 40) to be associated with the
proximity tag. Alternatively, scroll to the two-digit user number and
,
press the [
] key. You will enter the New Code Edit menu.
3. Enter the four- or six-digit New Code. The LCD will prompt you to swipe
your proximity tag. Otherwise, press the [#] key to exit.
4. Present your proximity tag to the keypad. If enrollment is successful,
acknowledgement beeps will sound and the keypad LCD will read 'Tag
Enrolled Successfully'. If the proximity tag has been enrolled previously,
,
an error tone will sound. The LCD will read 'Duplicate Tag/User Code'.
] to select.
5. The keypad will return to the User Code Edit Select menu.
Description
If Ready light is ON, the system is ready to arm.
If Armed light is ON / Flashing, the system has
been armed successfully.
ON -Indicates that a system trouble is active.
Flashing - Keypad low battery.
ON -Indicates that AC is present at the keypad.
System is
Ready to Arm
< >
Deleting Proximity Tags
Delete the prox tags from the system when they are lost or no longer needed.
1. Enter [,][5] [Master Code] on the keypad.
2. The keypad will display the user number and include the letter 'T' if a
prox tag is programmed.
3. Enter or select the User Code slot you wish to delete.
,
4. Press [
] to delete both the user code and the proximity tag.
NOTE: User codes can only be deleted individually.
NOTE: User 40 - Master Code cannot be deleted; a deletion attempt on
this user code will delete the proximity tag only.
NOTE: A user code, once deleted, must be re-enrolled before it can be
used again.