Setting the threshold
Caution: The threshold can still be set when the sensor is on.
The LEDs will remain lit during potentiometer
rotation (2, 3*). The LEDs will go off if potentiometer
rotation is interrupted for approximately
15 seconds or stopped.
• Briefl y press the mode button (1)
• Turn the Sun (2) or Temperature (3*) potentiometer fully clock-
wise to the (+) position.
The Sun (4) or Temperature (5*) LED will light up/fl ash
"red".
• Slowly turn the Sun (2) or Temperature (3*) potentiometer
anticlockwise (-) until the LED (sun or temperature*) changes
from "red" to "green".
The current light/temperature value is set as the threshold
value (value where a command will be performed).
* only on Thermosunis
Page
12
/
2
Copyright © 2008 Somfy SAS. All rights reserved.
4
1
3*
5*