Jandy ePump Pro Serie Manual De Instalación Y Operación página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Jandy
®
The Jandy Pro Series ePump + SVRS is capable of generating system pressures up to 50 psi. Installers
must ensure that all system components are rated to withstand at least 50 psi. Over pressurizing the
system can result in catastrophic component failure or property damage.
To minimize risk of severe injury or death, the filter and/or pump should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements
are generally not intended to apply to the pool equipment, such as filters or pumps.
Jandy pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include
the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed
and secured before testing.
RELEASE ALL AIR in the system before testing.
Water pressure for test must NOT EXCEED 35 PSI.
Water temperature for test must NOT EXCEED 100°F (38°C).
Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult the
equipment manufacturer.
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other
equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your
equipment.
Do not start pump dry! Running the pump dry for any length of time will cause severe damage and will
void the warranty.
This pump is for use with permanently installed pools and may also be used with hot tubs and spas,
if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on
the ground or in a building, such that it cannot be readily disassembled for storage. A storable pool
is constructed so that it may be readily disassembled for storage and reassembled to its original
integrity.
Do not install beneath the skirt of a hot tub. The pump requires adequate ventilation to maintain air
temperature at less than the maximum ambient temperature rating listed on the motor rating plate.
For Canadian installation, this pump carries a Type 3R enclosure rating and therefore is not intended
for installation in areas subjected to windblown dust.
Install the pump such that any disconnecting means and/or junction boxes for power connection are
within site of the pump and at least five (5) feet from the inside wall of the pool and spa. Canadian
installations require a minimum of three (3) meters from the pool water.
Refer to the "Bonding" instructions in section 3.2 of this manual and consult local & national
codes for using a No. 8 AWG or larger conductor to properly bond the pump motor to other metal
components and electrical equipment in the vicinity of the pool/spa.
|
Pro Series ePump
w/SVRS
Installation and Operation Manual
WARNING
WARNING
WARNING
CAUTION
CAUTION
ENGLISH
Page 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Epump jep2.0svrsPro serie epump svrs

Tabla de contenido