Technical Data; Operation Instructions - Urrea SOLT1020-BV Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL DATA

SOLT1020-BV
INPUT VOLTAGE
FREQUENCY
PHASES
EFFICIENCY
CURRENT RANGE @ 110 V
CURRENT RANGE @ 220 V
WELDING CURRENT @ 110 V (60%)
WELDING CURRENT @ 220 V (60%)
PROTECTION CLASS
POWER FACTOR COS ɸ
WORK CYCLE
WEIGHT

OPERATION INSTRUCTIONS

PREPARING YOUR WORK AREA
1. You must have a sturdy work table that is
open below the area you are cutting. Molten
slag will be blown through the work metal, and
must be able to fall away freely
2. Your work table must allow the work metal
to be firmly clamped to prevent it accidentally
falling or moving.
3. The floor and surrounding area of your work
site must not be flammable. A clean cement
floor is recommended. The cutting process will
eject molten metal slag onto the floor, and it
will scatter for 8-10 feet or more in any direc-
tion. Have an adequate fire extinguisher avail-
able if needed.
ASSEMBLY
Grounding the tool and attach air supply:
1. Attach a ground wire (not supplied)
to the screw in the lower the back of
the machine. Connect the other end
of the wire to an appropriate ground,
such as a steel workbench, steel biding member
or grounding electrode.
2. Connect the gas air inlet to your
supply Argon by one air hose (not
supplied). And remember to fasten
it with coupling.
WARNING: Only use dry Argon as the gas in
this tool. Use of any other gas, such as oxygen,
acetylene, etc. may cause explosion.
16
OPERATION
NOTE: Before beginning, please read and
understand all the safety precautions staring
(110 / 220) V ~
on page 1 and especially the section "Specific
60 Hz
Safety Rules".
1 ~
1. Mount the metal to be cut to the metal
ɳ 85%
...
weeding-cutting table. It should be mounted so
TIG: (10 - 150) A
...
MMA: (10 - 120)
that the cutting debris falls to the cement floor.
...
TIG: (10 - 200) A
2. Place the welder unit no closer than six feet
...
MMA: (100 - 160) A
from the workpiece to be cut.
...
TIG: (30 - 100) A
3. Connect the TIG torch control, cable plug, and
...
MMA: (20 - 85) A
gas outlet hose. Twist to lock in place.
...
TIG: (30 - 200) A
...
MMA: (20 - 170) A
4. Plug in the Grounding Cable into the Ground
IP21S
Connector on the lower left of the unit front.
0,7
Twist to lock.
35 %
5. Securely place the clamping end of the
12 kg (26,4 lb)
Grounding Cable Clamp to a part of the work-
piece or metal table that is clean of paint, oil, or
dirt. Clamp as close as possible to the workpiece
without damaging the cable during welding.
6. Assemble the desired accessories and rod in-
side the tip of the TIG Torch handle.
7. Connect a hose and coupling from the gas
regulator on an Argon gas tank (none included)
to the Argon Gas Inlet on the back of the unit.
Follow the gas cylinder manufacturer's instruc-
tions for set-up and use.
8. Verify that the Power Switch is in the off posi-
tion, then plug the 220 V~ line cord plug into an
appropriate 220 V~ outlet.
9. When everything is in place for welding,
press the Power Switch UP to the ON position.
The Power will be on, but the Torch is not yet
energized.
10. Press the torch and orient yourself to one
side of the area to be welded, and move the
Welding Helmet Face Shield (not included) over
your eyes.
gized. Be careful not touch anything else with
the Torch except the workpiece to be welded.
DANGER! To prevent serious injury and death:
The TIG Welder will immediately turn on when
the trigger is held down.
11. Direct torch away from people and flam-
mables, while you press (and hold) the Torch
Handle Trigger to energize the Torch Electrode.
a. Unscrew the Ceramic Nozzle on the Torch
Handle.
b. Unscrew the Collect Housing.
c. Place a 5/32" prepared tungsten welding
rod (not included) into the torch.
d. Screw the Collect Housing and Ceramic
Nozzle back onto the Torch.
CAUTION: The Torch handle is now ener-

Publicidad

Tabla de contenido
loading

Tabla de contenido