Descargar Imprimir esta página

Gima 28066 Guía De Uso página 19

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
19
Appendix II
Guidance and manufacturer's declaration – electromagnetic emissions for all EQUIPMENT and SYSTEMS
Guidance and manufacturer's declaration – electromagnetic emission
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Emission test
RF emissions CISPR 11
RF emission CISPR 11
Guidance and manufacturer's declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS
Guidance and manufacturer's declaration – electromagnetic immunity
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD) IEC 61000-4-2
Power frequency
(50/60Hz) magnetic
field IEC61000-4-8
NOTE: U T is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer's declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not
LIFE-SUPPORTING
Guidance and manufacturer's declaration – electromagnetic immunity
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Immunity test
IEC 60601 test level
Radiated RF
10 V/m
IEC 61000-4-3
80 MHz to 2.7 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
Compliance
Group 1
Class B
IEC 60601 test level
Air Discharge: ±2 kV,
±4 kV, ±8 kV, ±15 kV
contact: ±8 kV air
30 A/m
Compliance
level
10 V/m
ENGLISH
Electromagnetic environment – guidance
The 28066 / NE-M01 uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
The 28066 / NE-M01 is suitable for use in all establishments, in-
cluding domestic establishments and those directly connected to
the public low-voltage power supply network that supplies buildings
used for domestic purposes.
Compliance level
Air Discharge: ±2 kV,
±4kV, ±8 kV, ±15 kV
contact: ±8 kV air
30 A/m
Electromagnetic environment
guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the 28066 / NE-
M01, including cables, than the recommended separa-
tion distance calculated from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
3.5
√P
d=
V
1
3.5
√P
d=
80MHz to 800MHz
E
1
7
√P
d=
800MHz to 2,7GHz
E
1
Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter man-
ufacturer and d is the recommended separation distance
in metres (m).
Interference may occur in the vi-
cinity of equipment marked with
the following symbol:
Electromagnetic environment
guidance
Floors should be wood, concrete or ce-
ramic tile. If floor is covered with synthetic
material, the relative humidity should be
at least 30 %.
Mains power quality should be that of a
typical commercial or hospital environ-
ment.

Publicidad

loading

Este manual también es adecuado para:

Ne-m01