DISSIPATION FACTOR
Range
0 ~ 1.999
Accuracy is ± ( % of reading+number of digits ).
Lx is inductance readout in counts.
Accuracy is applied when L is from 20 to 100% of full scale range in parallel
mode measurements.
Parallel Mode
Series Mode
D
NOTE : ALL THE ACCURACY IS GUARANTEED AT TEMPERATURE
OF 15℃ TO 28℃, RELATIVE HUMIDITY TO 80% AND HALF
YEAR CALIBRATION CYCLE.
3.3
GENERIAL SPECIFICATIONS
Power
Display
Low Battery Warning
Current Consumption 17.3mA
Temperature
Dimensions
Weight
Standard Accessories
Optional Accessories Measurement clip TL-8 for SMD type component
Lx≦200mH
1
%
+
10
Lp
π
=
2
D
f
L
Rp
Rs
=
L
π
2
fLs
Single 9V 006P Battery
0.5
digital height, 3 1/2 digits liquid crystal
〞
display with "LOBAT" and decimal annunciates
Display will show "LOBAT" in the last 5% of
Battery life
0℃ ~ 40℃, Operating
-20℃ ~ 70℃, Storage
177×88×40mm
400 gram
Test Clips (red & black) 1 pair
Operation Manual
Accuracy
200mH<Lx<200H
2000
+
Lx
Ls
1
13
2000
2
%
+
20
+
Lx
Lp
Rp
Rs
piece