en
Error code
F1
F2
F3
F4
F5
F6
The filter may give off odours under special operating conditions. Turn the machine off and replace
the filter if necessary.
15.7
Order numbers and replacement parts
Article number
3400 800
3400 868
3400 869
48
Error description
Pre-filter is not detected / missing.
The fan and the plasma electrode turn off.
No plasma cleaning takes place and the
fan is turned off.
Fan blocked / faulty.
The plasma electrode turns off. No plasma
cleaning takes place and the fan is turned
off.
3-stage filter cartridge is not detected.
The plasma electrode turns off. No plasma
cleaning takes place and the fan is turned
off.
Internal communication error.
The machine turns off.
Plasma voltage is too low.
There is no plasma cleaning.
Plasma voltage is too high.
There is no plasma cleaning.
EAN
4003718054200
4003718055245
4003718055252
Error rectification
Check to ensure that the pre-filter is positio-
ned correctly.
Turn the fan on manually by press the "+"
button.
You can only turn on the fan when there is
no longer an F1 error on the machine.
If the machine will not start, send the
machine for service.
Send the machine for service.
Check to ensure that the 3-stage filter cart-
ridge is positioned correctly.
If the machine will not start, send the
machine for service.
Turn the machine on.
If the machine will not start, send the
machine for service.
Turn the machine off and then on again
after several seconds.
This error can occur when the machine is
being operating using a highly fluctuating
mains voltage.
If the machine will not start, send the
machine for service.
Turn the machine off and then on again
after several seconds.
If the machine will not start, send the
machine for service.
Article description
AL-KO PURE air purifier
3-stage filter cartridge
Pre-filter
AL-KO PURE
3400857_a