NE JAMAIS LAISSER LA CHAUFFERETTE SANS
SURVEILLANCE LORSQU'ELLE EST ALLUMÉE!
I.) PUMP PRESSURE ADJUSTMENT
Modèles DFA-45T/70T/125T
- Remove pressure gauge plug from end filter cover.
- Install accessory pressure gauge.
- Start heater (See Operation, page 9)
Allow motor to reach full speed
- Adjust pressure (Using a flat blade screwdriver)
Turn relief valve to right to increase pressure.
Turn relief valve to left to decrease pressure.
Set pump pressure below correct for pressure for
each model.
- Stop heater (See Operation, page 10)
- Remove pressure gauge. Replace pressure gauge
plug in end filter cover.
MODÉLE
DFA-45T
DFA-70T
DFA-125T
Modèles DFA-170C/210C
- Start heater (See Operation, page 9)
Allow motor to reach full speed.
- Adjust pressure (Using a flat blade screwdriver).
Turn relief valve to right to increase pressure.
Turn relief valve to left to decrease pressure.
Set pump pressre below correct for pressure for
each model.
- Stop heater (See Operation, page10)
MODÉLE
DFA-170C
DFA-210C
NOTA : N'utiliser que des pièces de remplacement pour l'équipement original. L'usage de pièces de
substitution ou de fabrication non générique annule la garantie et peut rendre l'appareil dangereux.
PRESSION DE LA POMPE
19.3kPa(2.8lb/po
25.5kPa(3.7lb/po
37.9kPa(5.5lb/po
PRESSION DE LA POMPE
44.8kPa(6.5lb/po
58.6kPa(8.5lb/po
14
Obturateur du
branchement du
manomètre
Soupape de
sécurité
Manomètre
Soupape de
sécurité