UNPACKING
• This luminaire has been properly packed so that no
parts should have been damaged during transit.
• Inspect to confirm.
2
hANDLING
• Damage may occur if luminaire is improperly handled
outside of pack.
• Do not impact or stack luminaire after removal from
packaging.
3
MOUNTING
Bird Shields (UL Units)
-
The bird shield behind slip fitter clamp comes with
an opening for 1 ¼ -inch (1.660 OD ) pipe.
-
If 2-inch pipe (2.375 OD) is used, bird shield is not
necessary, and should be discarded.
• IEC Units are provided with a factory installed
gasket for use with only a 48mm diameter pipe.
Risk of injury. The luminarie should be mounted so that
prolonged staring into the luminaire at a distance closer
than 0.50m is not expected.
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
Risk of injury. Do not rely on door latch to hold power
module door during installation/maintenance. The door latch
is provided only to aid in the fastening of the captive screw.
For installation to mounting arm:
• The pipe clamp accommodates 1 1/4 inch ((1.660 OD)
through 2 inch (2.375) pipe. If necessary, adjust the two
pipe clamp bolts so that opening is slightly larger than
pipe size being used.
CAUTION
WARNING
WARNING
• Birdshield behind slipfitter clamp comes with an o pening
for 1 1/4 inch pipe. If a larger pipe size is used, bird shield
is not necessary, and should be discarded.
• Insert mounting arm carefully through bird-shield
(if required) and into back of the luminaire until it hits the
leveling steps which stick down from top of housing.
• By selecting different steps, the luminaire may be
adjusted up or down with respect to pipe. A pad is
provided on top of housing for convenient application
of hand level.
• To mount, hold luminaire approximately level and
snug up bolts (4-5 foot-pounds).
-
If more upward tilt of front of luminaire is needed,
loosen the bolts slightly, lift luminaire and insert it
to the next set of leveling steps.
-
If downward tilt is needed, reverse procedure by
extracting the luminaire from the mounting arm
to sit on a more rearward set of steps.
• Once the proper level has been achieved, tighten
each bolt to 10-12 foot-pounds, alternating between
bolts.
-
If a torque wrench is not available, correct torque
may be achieved by turning bolts two to three full
turns (or until bottoming occurs) past their snug
position.
Under no conditions should bolts be torqued to level greater
than 12 ft-lbs. (16.3 N-m)