Instruction manual
WATER DRAINAGE
Manual(Figure 12)
•
Once the unit shuts down upon full water, turn off the unit and unplug
the power plug.
•
Put a tray for the water below the water outlet at the back of the unit.
•
Screw off the drain cap, unplug the water plug and water will flow out.
•
Tilt the unit slightly backward when draining.
•
If the water tray is full before the unit is empty block the water outlet
with the water plug as soon as possible to prevent the water from
flowing onto the ground or carpet.
•
Once the water is fully drained, insert the water plug and screw on the
water cap tightly.
•
Turn on the unit only after the water plug and drain cap are installed properly;
otherwise, the condensate of the unit will flow onto the ground or carpet.
Continuous drain (Figure 13 + 14)
1. Screw off the water cap insert a 13mm PVC drain hose 8mm-10mm into
the water outlet.
2. Connect the drain hose to the toilet or outdoor.
3. When operating in the heating mode, adopt continuous drain; other-
wise, the unit may shut down due to full water.
4. Put the drain hose in an inaccessible place at a height not above the
water outlet and keep the drain hose free from flexure.
Maintenance and Servicing
Prior to maintenance and servicing of the unit, turn off the power and
unplug the plug.
•
Clean the surface of the unit with wet soft cloth. Do not use chemical
solvents such as alcohol and gasoline; otherwise, the surface of the air-
conditioner may be damaged.
•
Clean the filters once every two weeks. If the filter frame and filter are
clogged with dust, the function of the air-conditioner may decrease
•
Take out the filter frame gently in the direction shown by the arrow (as
shown in Figure 15 + 16).
•
Put the filters into warm water (about 40°C) to which neutral cleaner is
added for cleaning and then dry them in the shade.
•
Make sure the filters are completely dry before placing them back in the
unit.
8
TROUBLESHOOTING
Problem/fault
Cause
indication
The air-conditioner
•
No power
does not work
•
Full water indicator
illuminates?
•
Ambient temperature too
low ?
•
The room temperature is lower
than the set temperature in the
cooling mode.
Bad cooling or heating
•
There is direct sunlight
effects
•
The doors and windows are
open, the room is crowded or
there are other heat sources
in the cooling mode
•
Filter mesh very dirty
•
Air inlet or air outlet clogged
Large noise
•
Air-conditioner not put on a
flat surface
The compressor does
•
Initiation of overheat
not work
protection.
The remote control
•
Too long a distance
does not work
•
The remote control does not
point toward the receiving
head of the remote control
•
The batteries have no
electricity
Display E1
•
Pipe temperature sensor
failure
Display E2
•
Room temperature sensor
failure
Display E4
•
Anti-freeze protection
Full water indicator
•
The water in the baseplate
illuminates
of the unit reaches the full
water level
Remedy
•
Connect the unit to a live
socket and turn it on.
•
Drain the water stored in the
unit.
•
It is recommended that this
unit be operated at 10-35°C.
•
Change the set temperature
•
Draw the curtain on.
•
Close the door and window
and add new air-conditioners
•
Clean or replace the filter
mesh
•
Remove the obstruction
•
Put the air-conditioner in a flat
and firm place (may reduce
noise)
•
Wait 3 minutes until the
temperature decreases and
then turn on the unit
•
Bring the remote control
close to the air-conditioner
and ensure that the remote
control points toward the
receiving head of the remote
control.
•
Replace the batteries
•
Check the pipe temperature
sensor and related circuits
•
Check the room temperature
sensor and related circuits
•
Restore the functions
automatically once defrozen.
•
Drain the water in the
baseplate.