Descargar Imprimir esta página

Beretta C.A.I 24 Manual De Instalacion Y Uso página 23

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
R.A.I.: programmable parameters
DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
3
INSULATION LEVEL OF BUILDING (+) (*)
10
DHW MODE
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
12
WATER TANK MAXIMUM SET-POINT
13
DELIVERY TERMPERATURE EXT. WATER TANK
14
DELTA EXTERNAL WATER TANK (ON)
20
CH MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
42
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
43
S.A.R.A. BOOSTER FUNCTION
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
85
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
MIX R.S.I.: programmable parameters
DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
2
BOILER POWER
3
INSULATION LEVEL OF BUILDING (+) (*)
10
DHW MODE
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
12
WATER TANK MAXIMUM SET-POINT
13
DELIVERY TERMPERATURE EXT. WATER TANK
14
DELTA EXTERNAL WATER TANK (ON)
20
CH MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
42
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
43
S.A.R.A. BOOSTER FUNCTION
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
85
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
(*) parameters shown only with external sensor connected and parameter 44 in 1 (AUTO).
(+) for well-insulated buildings select values close to 20, for badly insulated buildings choose values close to 5.
Parameter 45 "Inclination of thermoregulation curve (OTC)"
The curve must be chosen according to the geographical area and the type of
installation.
UNIT OF
MIN
MEASURE
1 Methane
2 LPG
3 Methane France
min
5
0 (OFF)
1 (Instantaneous)
2 (Mini-tank)
3 (Ext. water-tank with thermostat - A & B cases)
4 (Ext. water-tank with sensor - C case)
°C
40
°C
50
°C
0
0 (OFF)
1 (ON)
2 (zone valves + remote control panel)
° C
45
min
0
min
0
-
0
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
°C
0
°C
0
UNIT OF
MIN
MEASURE
1 Methane
2 LPG
3 Methane France
26 (26kW)
30 (30kW)
34 (35kW)
min
5
0 (OFF)
1 (Instantaneous)
2 (Mini-tank)
3 (Ext. water-tank with thermostat - A & B cases)
4 (Ext. water-tank with sensor - C case)
°C
40
°C
50
°C
0
0 (OFF)
1 (ON)
2 (zone valves + remote control panel)
° C
45
min
0
min
0
-
0
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
°C
0
°C
0
Tm. - 20
OTC = 10 x
20 - Te.
23
MAX
DEFAULT
(setted in factory)
(setted by techn. assist. centre)
1-2
20
5
3
80
60
80
80
10
5
1
80
80
20
15
20
3
1
0
1
1
40
20
10
4
10
6
MAX
DEFAULT
(setted in factory)
(setted by techn. assist. centre)
1-2
30
20
5
3
80
60
80
80
10
5
1
80
80
20
15
20
3
1
0
1
1
40
20
0
1
10
4
10
6
T m. = maximum rated temperature of heating water
T e. = minimum rated external temperature
PARAMETERS
60
40
1
1
1
0
1
1
0.6
PARAMETERS
60
40
1
1
1
1
0.6

Publicidad

loading