Technical data

Type:
Polar pattern:
Frequency range:
Sensitivity at 1,000 Hz:
Electrical Impedance:
Recommended load impedance:
Hum Sensitivity (at 50 Hz):
Equivalent noise level to IEC 60268-4
(A-weighted):
Maximum Sound Pressure (for 1 %
T.H.D. at 1,000 Hz into 600-ohm load):
with –14 dB attenuation:
Climatic Conditions
temperature range:
Rel. humidity:
Powering:
Current consumption:
C535 EB MANUAL
TEcHNIcAL dATA
condenser transducer, prepolarized
cardioid
20 ... 20,000 Hz ±3 dB from published
curve
7 mV/Pa ≙0.7 mV/µbar
(–63 dBV, re 1 µbar)
200 ohms, ±20 % balanced
≥600 ohms
4 µV/5 µT
21 dB-A
80 Pa≙130 dB SPL
400 Pa≙144 dB SPL
min. –20° C, max. +60° C
99 % (at +20° C
9–52 V (acc. to IEC 61938)
approx. 1 mA