Chart of Indicators

Explanation
Display of Indicators
Battery being charged
Battery fully charged
Electrical system is
turned on
Pilot Light is lit
Hot water warning
(chamber)
Hot water warning
(water outlet)
Tilt warning
Flames out warning
Low battery warning
Low water flow
warning
Explanation
Display of Indicators
Battery being charged
Battery fully charged
Pilot Light is lit
Water is running
Hot water warning
(chamber)
Hot water warning
(water outlet)
Tilt warning
Flames out warning
Low battery warning
Low water flow
warning
MODEL 2302-B
Trigger
Water temperature at heat
exchanger exceeds 131°F.
Water temperature at water
outlet exceeds 122°F.
Heater is tilted more than 30
degrees.
Flames out / pilot light out
In-house battery voltage is
lower than 9.8V.
Water flow rate is lower that
0.4 gallon (1.5 L)/min.
MODEL 2302-A
Trigger
(animated)
Water temperature at heat
exchanger exceeds 131°F.
Water temperature at
water outlet exceeds
122°F.
Heater is tilted more than
30 degrees.
Flames out / pilot light out
In-house battery voltage is
lower than 9.8V.
Water flow rate is lower
that 0.4 gallon (1.5 L)/min.
Steady light:
Flashing light:
/
/
(Red / Yellow / Green)
(Red / Yellow / Green)
System Reaction
Gas will be cut off immediately. Pump will
be shut off in 30 seconds.
Gas will be cut off immediately. Pump will
be shut off in 30 seconds.
Gas & pump will be shut off immediately.
Gas & pump will be shut off immediately.
Gas & pump will be shut off immediately.
2 seconds after the first warning is
signaled, system will detect the flow rate
again; if the flow rate is still lower than the
specified level, gas & pump will be shut off.
System Reaction
Gas will be cut off immediately. Pump will be
shut off in 30 seconds.
Gas will be cut off immediately. Pump will be
shut off in 30 seconds.
Gas & pump will be shut off immediately.
Gas & pump will be shut off immediately.
Gas & pump will be shut off immediately.
Gas & pump will be shut off 2 seconds later
/
/
Corrective Action
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Corrective Action
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.