3.1
Technical features
Description
Heat output provided with HP in operation
Total heat output
Heating time (
)
1
Heating time in BOOST mode (
Tank dispersion
Electrical specifications
Power supply
Frequency
Protection degree
Max. consumption HP
Average consumption
Max. resistor consumption + HP
Electrical resistor output
HP maximum current
Required overcurrent protection
Internal protection
Operating conditions
Heat pump air input min.-max. temperature
(R.H. 90%)
Installation room min.-max. temperature
Operating temperatures
Maximum temperature that can be set for HP
in ECO mode
Maximum temperature that can be set for HP
in AUTOMATIC mode
Unit
kW
kW
H:M
H:M
)
1
W
V
Hz
kW
kW
kW
kW
A
A
°C
°C
°C
°C
DOCUMENT 6328408
Installation, use and maintenance manual
ECOMAXI 260 ErP
1.82
3.4
10:14
5:06
70
1/N/230
50
IPX4
0.53
0.43
2.03
1.5
2.4
16A T fuse / automatic 16A switch, characteristic
C (during installation on supply system)
Single manual-reset safety thermostat on resistor
-7-38
5-38
56
70
ECOMAXI 260 S ErP
1.82
3.4
10:14
5:06
71
0.53
0.43
2.03
1.5
2.4
56
70
47