WANDA - WANDA CLASSIC
Room heating takes place:
a)
By irradiation: through the panoramic glass and the external hot surfaces of the stove, the heat is radiated into the environment;
b)
By natural convection: the passage of air through the coating and the covering hood releases heat in the
c)
By forced convection: a ventilation kit suitable to improve the distribution of heat by ventilation only either of the installation room
or of the adjacent local.
ACCESSORIES
WANDA
WANDA CLASSIC
The device is equipped with registers of primary and secondary air.
A- PRIMARY air register
With the primary air control
direction. The primary air is necessary for the combustion process. The ash drawer must be regularly emptied, so that the ash does not
obstruct the primary air entry. Through the primary air the fire is also kept alive.
During wood combustion, the register of primary air must be opened only for a while, because otherwise the wood burns fast and the
stove may overheat. For the correct arrangement (see chapter Normal operation).
B - SECONDARY air register
Over the door of the hearth there is the secondary air control
moved to the right), especially for wood combustion, so that un-burnt carbon does not undergo a post-combustion. See chapter Normal
operation. Through this register it is possible to adjust the power of the stove.
Leaving it slightly open, according to the flue of the chimney, it is possible to keep the glass clean.
The adjustment of the registers necessary to reach the rated calorific yield is the following one:
WANDA
WANDA CLASSIC
C - AIR REGISTER for the heating of the environment
This register, through a fan controlled by a thermoregulator pos. D, adjusts the warm air output ONLY from the front side of the appliance.
D - FAN ELECTRIC THERMOCONTROLLER
UNIT OPERATION.
This electronic thermocontroller for packaged units manages ventilation air flows.
The unit is switched on or off by pressing and holding the 1 button. During operation
the display shows the set speed alternating with unit status, led 9.
When the unit is off, the display also remains off.
The unit can be controlled MANUALLY or AUTOMATICALLY.
MANUAL mode
To access MANUAL mode, press the 2 button; when the 3 light comes on the function
is active. The 4-5 buttons are used to select one of the five fan speeds, also active
when the flue is cold.
The motor is started in automatic mode by a mechanical thermostat (the display
shows WAIT), which is activated when the temperature is at least 45°C (fixed value,
not modifiable). The 6 led indicates that the thermostat contact is closed.
AUTOMATIC mode
To access AUTOMATIC mode, press the 2 button; when the 7 light comes on the function is active. Use the 5 button to set the speed.
The 4-5 buttons are used to select one of the five fan speeds.
In automatic mode the COMFORT temperature can also be selected. Press the 4 button to access the COMFORT temperature setting
and then set the value using 4-5. This setting allows the user to reduce fan noise when the room temperature measured by the probe
inside the controller exceeds the comfort set point; the motor operates one speed lower (this mode has no effect in first speed) and is
signalled by the 8 led.
LANGUAGE menu.
Pressing and holding the 2 button accesses the LANGUAGE menu, where the display language can be changed using the 4-5 buttons
(IT, EN, DE, FR). Pressing the 2 button briefly again accesses the DISPLAY menu, where the brightness can be adjusted (between 10
and 150). Pressing the 2 button briefly another time accesses the DEGREES menu, where the temperature display can be set as °C
or °F.
BUZZER menu
Pressing the 2 button briefly a final time accesses the buzzer menu, where audible buzzer can be enabled or disabled.
REMOTE CONTROL OPERATION:
The electronic controller for packaged units can be managed by an IR remote control.
• The controller is switched on or off by pressing and holding the 11-12 buttons.
• To switch from MANUAL to AUTOMATIC on the IR remote control press the 13-14 buttons. The LED corresponding to the operating
mode comes on, manual 3 or automatic 7.
7097030
POKER
SERIES
SERIES
(Picture 7 at page 70
- A) is adjusted the passage of air through the ash drawer and the grate in the fuel
Hourly consumption in Kg/h
2,8
2,8
(Picture 7 at page
GLOVE
SERIES
SERIES
(Picture 7 at page 70
PRIMARY air
CLOSED
CLOSED
(Picture 7 at page 70
pos. C).
pos. D).
- B).This regulator must be open (the lever must be
SECONDARY air
TERTIARY AIR
1/2 OPEN
PRE - ADJUSTED
1/2 OPEN
PRE - ADJUSTED
3
7
A
2
4
A
5
6
7
7
8
1 2 3 4
room.
9
8
6
OK
5
1
O1