Solutions To Most Frequent Anomalies; Electrical Connection - Sima CEL-36 P Manual De Instrucciones

Ocultar thumbs Ver también para CEL-36 P:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
STEPS TO FOLLOW TO REALISE A CUTTING
1 Lift slightly the blades safeguard to save height of the flange and then drag it completely leftwards Fig.6
before you can lift it totally.
2 Resting the bars upon the roller so that you can easily move the bar forward as per the predetermined
measurement. Place the bar in the throat between the two blades. Lower back the blades safeguard and pus hit
rightward to free the pedal (the mechanism that operates the cutting).
Note: CEL models are equipped with a safety system that when the blades safeguard is lifted, the blades would not
be able to cut the material.
3 Once the safeguard has been released, we can effectuate a cutting, either by pressing the pedal or pulling
the grip.
Never try to make a cut while the safeguard is lifted as the material to cut can leave the cutting throat and
cause damage.

5. SOLUTIONS TO MOST FREQUENT ANOMALIES

ANOMALY
Motor does not start
Motor starts very slowly and takes too
long to reach its revolutions
Cutting power is too low
Premature wearing of the belts

6. ELECTRICAL CONNECTION

The extension cable used to feed the machine needs to have a minimum section of 4x2.5 mm
meters long. For a superior distance 4x4 mm
normalised aerial of 3P+T or 3P+N+T compatible with the machine switch and in the other end, one normalised aerial
pin of 3P+T ó 3P+N+T compatible with switchboard exit.
Machines with electrical motor should always be connected to a normalised switchboard that disposes of a
magneto-thermal switch and a differential in accordance with the characteristics of the motor:
3Kw /4 CV, three phase at 400V, 15A magneto-thermal and 15A/30mA differential.
4Kw / 5.5 CV, three phase at 400V, 10A magneto-thermal and 10A/30mA differential.
The machine electrical tension is visible on the voltage indication next to the top of engine terminals and on the
machine characteristics plate.
WARNING: Do not plug the machine to the electricity if you are not sure of the available electrical tension.
If the tension is not correct, the engine will undergo irreparable harm or out of service.
WARNING: Never manipulate the power cables or any electrical equipment of the machine, if you have not
totally unplugged the machine from the electricity.
Once you have brought the rotation direction of the engine back, the machine is ready to operate.
POSSIBLE CAUSE
Fault of the electrical power supply
activation of the thermal protection of
the single-phase switch
Switch damaged
Condenser damaged.
(Single-phase motors)
Belt loose or blunt
Blades blunt
Power drop down of the motor
The belts slide over the pulleys
2
can be used. In one of its ends, it is needed to connect a base
7-
SOLUTION
Check the power supply in the switch
board. Check the position of the circuit
breaker and the residual current device
in the switch board.
Make sure the extension cable is in good
state and its fitting in the two extremes is
correct.
Wait until the motor has cooled down
and re-activate the thermal protection
Replace it
Replace it
Tighten the belt or replace it
Change the cutting face of the blade
or replace it
Let the technical service check the
motor.
Tighten the belts
2
up to 25
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cel-42 pCel-52 pCel-55 p

Tabla de contenido