Toshiba RAV-SM562CT-E Manual De Instalación página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 108
Procedure
If there is other indoor unit to be changed, repeat
procedure
When the above setup has finished, push
select the indoor unit No. before change of setup, specify
ITEM CODE [12], [13], [14] in order with temp. setup
/
6
Address change check Before change:
[3-3-1] → After change: [2-2-2]
Pushing CL button clears the contents of which setup was changed.
(In this case, procedure from
After check of the changed contents, push
display disappears and the status becomes the usual stop status. (When pushing
from the remote controller is not accepted for approx. 1 minute.)
* If the operation from the remote controller is not accepted even
7
1 minute or more passed after pushing
considered that the address setup is incorrect.
In this case, the automatic address must be again set up.
Therefore repeat procedure of the setup change from the Procedure
To recognize the position of the corresponding
indoor unit though the indoor unit No. is known
Check the position during operation stop.
(Be sure to stop operation of the set.)
Procedure
Push simultaneously
After a while, the display part flashes and the display appears as shown below.
In this time, the position can be checked because fan and flap of the indoor unit operate.
• For the group control, the indoor unit No. is displayed as [
fans and flaps of all the indoor units in the group control operate.
1
Check the displayed ITEM CODE is [01].
• When the ITEM CODE is other than [01], push
erase the display and repeat procedure from the first step.
(After pushing
is not accepted for approx. 1 minute.)
In the group control, every pushing
2
In this time, the position of the indoor unit can be confirmed because only fan and flap of the selected indoor
unit operate. (For a group control, No. of the firstly displayed indoor unit becomes the header unit.)
After confirmation, push
usual mode.
When pushing
3
becomes the usual stop status.
(When pushing
is not accepted for approx. 1 minute.)
2
5
to
to change the setup.
buttons, and then check the changed contents.
2
is repeated.)
TEST
VENT
+
buttons for 4 seconds or more.
TEST
button, operation of the remote controller
TEST
button to return the mode to the
TEST
button, the display disappears and the status
TEST
button the operation from the remote controller
Description
Indoor unit No. before setup change is displayed.
UNIT
to
TEST
button. (Setup is determined.) When pushing
TEST
button, it is
Description
ALL
TEST
button to
UNIT
button, the indoor unit No. in the group control is displayed in order.
24
SET
DATA
SETTING
TEST
UNIT No.
R.C.
SET
DATA
SETTING
TEST
UNIT No.
R.C.
SET
DATA
SETTING
TEST
UNIT No.
R.C.
TEST
button the operation
1
.
SET
DATA
SETTING
TEST
UNIT No.
R.C.
TEMP.
TIMER SET
TIME
SWING/FIX
FILTER
RESET TEST
SET CL
3
] and
SET
DATA
SETTING
TEST
UNIT No.
R.C.
(
Display changes according
to the model No. of indoor unit.)
CODE No.
No.
CODE No.
No.
CODE No.
No.
TEST
button, the
CODE No.
No.
ON / OFF
FAN
MODE
1
VENT
2
UNIT
CODE No.
No.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido