Descargar Imprimir esta página

GPI TM Serie Manual De Usario página 6

Ocultar thumbs Ver también para TM Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SPECIFICATIONS
Inlet and Outlet:
Spigot (Pipe) End Models:
TM050/TM050-P 1/2 inch Schd. 80,
TM075/TM075-P 3/4 inch Schd. 80,
TM100/TM100-P 1 inch Schd. 80,
TM150/TM150-P 1-1/2 inch Schd. 80,
TM200/TM200-P 2 inch Schd. 80,
NPT Models:
TM050-N/TM050-N-P
TM075-N/TM075-N-P
TM100-N/TM100-N-P
TM150-N/TM150-N-P
TM200-N/TM200-N-P
Design Type: Turbine
Wetted Components:
Housing: PVC
Journal Bearings: Ceramic
Shaft: Tungsten Carbide
Rotor and Supports: PVDF
Retaining Washer: Stainless Steel
Fitting Types: Spigot - Schd. 80 or NPT (female)
Max. Working Pressure: 225 PSIG @ 73° F
U.S. Measurement
Unit of Measure: Gallon
Flow Range:
1/2 inch
1 - 10 GPM
3/4 inch
2 - 20 GPM
1 inch
5 - 50 GPM
1-1/2 inch
10 - 100 GPM
2 inch
20 - 200 GPM
Accuracy with Computer: ± 3.0% of reading
(Accuracy can be improved with field
calibration)
Operating Temperature: +32° to +140° F
(Do not allow fluid to freeze inside meter.)
Storage Temperature: –40° to +158° F
*
Product Weight:
Spigot (Pipe)
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inch
6
Spigot (Pipe)
Spigot (Pipe)
Spigot (Pipe)
Spigot (Pipe)
Spigot (Pipe)
1/2 inch NPT
3/4 inch NPT
1 inch NPT
1-1/2 inch NPT
2 inch NPT
NPT
.38 lbs.
.55 lbs.
.43 lbs.
.67 lbs.
.49 lbs.
.84 lbs.
.66 lbs.
1.38 lbs.
.78 lbs.
1.78 lbs.
Dimensions - Inches (W x H x L):
Without Fitting
1/2"
2.0 x 2.6 x 3.8 2.0 x 2.8 x 5.5
3/4"
2.0 x 2.7 x 3.8 2.0 x 2.9 x 5.5
1"
2.0 x 3.1 x 4.1 2.0 x 3.3 x 6.2
1-1/2" 2.1 x 3.7 x 5.4 2.3 x 3.9 x 7.6
2"
2.4 x 4.2 x 5.5 3.5 x 4.5 x 7.9
*
Weight with computer display. Conditioned
signal output module adds .30 lbs.
**
Dimensions with computer display. Conditioned
signal output module adds 1.1 inch to height.
Metric Measurement
Unit of Measure: Litre
Flow Range:
1/2 inch
3.8 - 38 LPM
3/4 inch
7.6 - 76 LPM
1 inch
19 - 190 LPM
1-1/2 inch
38 - 380 LPM
2 inch
76 - 760 LPM
Accuracy with Computer: ± 3.0% of reading
(Accuracy can be improved with field
calibration)
Operating Temperature: 0° to +60° C
(Do not allow fluid to freeze inside meter.)
Storage Temperature: –40° to +70° C
*
Product Weight:
Spigot (Pipe)
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inch
Dimensions - cm (W x H x L):
Without Fitting
1/2"
5.0 x 6.6 x 9.6
3/4"
5.0 x 6.8 x 9.6
1"
5.0 x 7.8 x 10.4
1-1/2" 5.8 x 9.3 x 13.7
2"
6.0 x 10.6 x 13.9 8.8 x 11.4 x 20.0
*
Weight with computer display. Conditioned
signal output module adds .14 kg.
**
Dimensions with computer display. Conditioned
signal output module adds 2.8 cm to height.
**
With Fitting
NPT
.172 kg
.249 kg
.195 kg
.304 kg
.222 kg
.381 kg
.299 kg
.626 kg
.354 kg
.807 kg
**
With Fitting
5.0 x 7.1 x 13.9
5.0 x 7.3 x 13.9
5.0 x 8.3 x 15.7
5.8 x 9.9 x 19.3

Publicidad

loading