1347D Puller Motor Parameter List - Atlanta Attachment Company 1347D Manual Tecnico

Tabla de contenido

Publicidad

Manual Técnico & Lista de Partes

1347D Puller Motor Parameter List

PARAMETER
RANGE
Do this first
*****
290
026
0-5
111
200-9900 rpm
119
1-3
153
0-50
161
0-1
220
1-55
270
0-5
272
020-255
436
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off
LED 6: Off.
LED 7: OFF, Stop at needle down.
LED 8: OFF
21
SUGGESTED/
SHIPPED/
VALUE
VALUE
****
0
0
040
1
35
0=CW
5
5
*50
0
* For Gearbox Driven Pullers
11347D PARAMETER DESCRIPTION (PULLER MOTOR)
Perform a master reset before programming, see below
Mode (Lockstitch) of operation. MUST SET THIS PARAMETER
FIRST!
F-026=0 to disable the EB401 selection after power on.
Maximum speed when "129" is 0, 1, or 2.
Linear Acceleration
Breaking power at standstill
Motor Rotation
Acceleration
No Hand Wheel Sensor
Drive ratio between motor pulley and driven pulley. The larger the
number, the slower the motor RPM. (42 RPM)
Use code "5913". This disables an input that was causing box to
0
reset itself.
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "311"
3. Press "E" once and "2.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E".
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "591"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.