Routine Maintenance; Parts Blowout Drawing - claber Aquadue DUPLO Evolution Manual Del Usaurio

Ocultar thumbs Ver también para Aquadue DUPLO Evolution:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Routine maintenance

US
• Clean impurities inside and outside the unit.
• Check that all wires are in good condition.
• Very carefully, disassemble the valve case and clean dirty areas with
Note: Depending on how hard/dirty water build-up is, the solenoid valve may
need to be replaced.

Parts blowout drawing

Description
1. 1-1/4" External ring-nut
2. Stainless steel filter
3. 3/4" Female faucet connector
4. NBR O-ring
5. Valve body
6. O-ring
7. 1/2" Female connector
8. Control panel
9. Flip-top lid
10. 9V Battery wire connectors
* wire cable must be UPWARD
** white side of the magnet must be UPFRONT
22
01_26_8410_DUPLO_USA_EN.indd 22
water only. When reassembling, make sure that valve wires are in the
upward position and the white side of the magnet is in the upfront posi-
tion. The entire operation requires extreme care to avoid damage and to
maintain warranty coverage.
11. Rain Sensor jumper
12. Screw M4x8
13. Spacer for solenoid
14. Bracket
15. Solenoid with upward cable*
16. Screws (x4) for magnet flange
17. Magnet group with bushing
and flange**
18. Piston
19. Membrane valve
03/07/14 13:46