Galvamet KompaKOne Manual De Instrucciones página 150

Placa de inducción
Ocultar thumbs Ver también para KompaKOne:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN 
E7
E8
E9
EA
EC
EH
No display
- Cyclic o Er31 or
Er47
Er22 – ER22
ER03 or
ER20
Cooking
level
switching to 0
L
Overvoltage power supply.
Incompatible software version between
the control and the induction hob.
Defective fan.
Defective induction temperature sensor.
Hardware error.
Two cooking zones assigned to the same
zone control.
The temperature is not changing after 5
minutes the hob has been turned on.
Faulty power connection.
Faulty control.
Defective induction hob.
Pot not suitable for induction.
Defective control.
Sensors evaluation fault, the control
turns off after 3,5-7,5 sec.
Constant activation of the sensors,
control is turning off after 10 sec.
Liquids or tools over the control.
Defective control..
Defective cooking zone
No errors!
Activated lock function.
Get in touch with the authorized service center quoting the
error code.
Get in touch with the authorized service center quoting the
error code.
Get in touch with the authorized service center quoting the
error code.
Get in touch with the authorized service center quoting the
error code.
Repeat configuration. If the problem persists get in touch
with the authorized service center quoting the error code.
Leave the hob cooling down. If the problem persists get in
touch with the authorized service center quoting the error
code.
Get in touch with the authorized service center quoting the
error code.
Use pots suitable for induction.
If the problem persists get in touch with the authorized
service center quoting the error code.
Get in touch with the authorized service center quoting the
error code.
Get in touch with the authorized service center quoting the
error code.
Clean the glass.
If the problem persists get in touch with the authorized
service center quoting the error code.
Get in touch with the authorized service center quoting the
error code.
Get in touch with the authorized service center quoting the
error code.
Deactivate lock function.
74 

Publicidad

Tabla de contenido
loading

Productos relacionados para Galvamet KompaKOne

Tabla de contenido