Press the OK key
Control unit software version
N. total manoeuvres (x 100)
N. manoeuvres since latest maintenance (x 100)
N. radio control devices memorised
param. 1
param. 2
end
param. . . .
logic
logic. 1
logic. 2
end
logic. . . .
radio
add. start
Add. 2ch
end
read
erase 64
COD RX
v
ITA
language
- +
FRA
- +
end
DEU
- +
ENG
- +
esp
PRG
default
end
autoset
end
l. s w adj
LIMIT SWITCH ADJUSTMENT
end
ACCESS TO MENUS Fig. 1
hidden button
hidden button
PRG.
+/-
2 2 F D
1 A 9 C
OK
OK
DIAGNOSTICS
OK
OK
OK
OK
* X = 0,1,...,9,A,B,C,D,E,F
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
01 t1
See RADIO MENU
0 1
OK
OK
DIAGNOSTICS and WARNINGS
DESCRIPTION
CODE
photocell test anomaly
Er01
safety edge test anomaly
Er02
photocell test anomaly
Er03
during opening
photocell test anomaly
Er04
during closing
Er1X *
hardware anomaly
Er2X *
encoder anomaly
Er3X *
amperostop anomaly
Er4X *
thermal cutout anomaly
Er5X *
communication anomaly
no-power anomaly
Er60
(restart)
buffer battery power
Er61
anomaly
power out-of-range
Er62
anomaly
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
ok 01
ok 01
NOTES
check photocell connection and/or pa-
rameter/logic settings
check safety edge connection and/or pa-
rameter/logic settings
check photocell connection during OP
and/or parameter/logic settings
check photocell connection during CL
and/or parameter/logic settings
check connections to motor
motor is moved manually and/or check
encoder and relevant wiring
make sure movement is not hindered
allow automated device to cool
check connection with accessory devices
and/or expansion boards or serial-con-
nected devices
there was a power loss. Board is now ac-
tive again
automated device running on battery
power
supply voltage not in 230V+/-10% range
LIBRA-C-LX - 13