DISPLAY WINDOW
Note: There is a thin protective sheet of clear plastic on the overlay
of the console that should be removed before use.
1)
STROKES: Counts up to 9900 or counts down to zero from preset value.
2)
SPM: Stroke per minute.
3)
CALORIES/PULSE: Auto scans the heart rate and calories expended during exercise. If
the computer does not detect a heart rate, only calories will display.
4)
PROFILE DISPLAY: Shows the intensity of workout, watts profile and SPM profile.
5)
WATTS: Shows the watts expended during exercise.
6)
TIME/500M: Estimated time to reach 500M.
7)
TIME: Measures total working time up to 99:59, or counts down to zero from preset
time.
8)
MESSAGE BAR: Shows the instruction message.
9)
METERS: Tracks total distance covered from zero up to 9999 meters, or counts down
to zero from the preset value. If the value exceeds 9999, the computer changes to
kilometers. For instance, 10.0 represents 10000 meters.
10) RACING DIAGRAM: Shows the competition status of user and computer.
POWER ACCURACY
This rower displays power on the console. The power accuracy of this model has been tested using the test method of EN957-7:1998 to ensure a power accuracy within a tolerance of ±10 %
for input power ≥50 W, and within a tolerance of ±5 W for input power <50 W.
Force applied to the handle was measured throughout the rowing stroke, as well as the stroke position of the handle. This information was used to calculate the energy applied to the rower,
and the value of the energy calculation was divided by the period of exercise time to calculate the average mechanical power (the input power) applied to the rower. The power accuracy of
the displayed power was verified by calculating this input power and comparing the displayed power to the input (measured) power using the following conditions:
Nominal stroke length: 792 mm
Resistance settings:
• Minimum resistance setting at nominal stroke speed of 25 strokes per minute
• Medium resistance setting at nominal stroke speed of 25 strokes per minute
• Maximum resistance setting at nominal stroke speed of 25 strokes per minute
In addition to the above testing conditions, the manufacturer tested the power accuracy using one additional resistance setting and nominal stroke speed. Then the power displayed was
compared to the input (measured) power.
12
3
2
1
10
4
9
5
6
7
8