Setting parameters:

Current status of the roller counter (register)
The water meter number related to the EDC
module
Pulse value of the modulator disc
Resetting of the status bits (tampering, error)
Resetting of all logger values
(in case of replacement of the water meter
and further use of the EDC module)
Setting of the pulse length (ms)
Setting of the output pulse value
Activation of the radio signal performs automati-
cally, as soon as the function "pulse enabled" is
activated and the EDC module scans 30 pulses
from the register. The current status of the roller
counter is programmable by means of the opti-
cal head using the front-mounted optical interface
of the EDC module. A ZENNER PC-software is
required for programming. The configuration is
made by means of a ZENNER software, the uni-
versal interface MinoConnect and the specific
ZENNER infrared optohead IrCombiHead.
5. Radio modules
The EDC wireless M-Bus radio modules are
available in T-(standard), optionally in S- or C-
mode. Various data telegrams are available. The
modules operate unidirectional and usually send
every 20 seconds. Special versions possible.
Number of digit rollers
Counter with 8 digit with modulator disc
6-digit counter with modulator disc (DN50-DN125)
6-digit counter with modulator disc (DN150-DN200)
Data telegram contents (wM-Bus)
The EDC module can be delivered with various
data telegrams:
Data protocols
Current value
Current data
Due date
Monthly value
Further 11 monthly
values
Status information 1
Status information 2
* Data telegram according OMS Spec., Transmission interval 20 sec.
** wM-Bus, manufacturer specific data telegram, Transmission
interval 15 sec.
Technical specifications EDC-radio:
wireless M-Bus unidirectional,
Transmission
T1 (standard), optionally
mode
S1, C
AES-128 nach OMS
Encryption code
(device specific, optionally
customer specific)
rent value, due date, current
Telegram
month value, history of the
contents
monthly values, status
information
Transmission
typically 20 s;
interval
other configurations possible
Transmission
25 mW
power
Pulse value
1 rotation = 1 litre
1 rotation = 10 litres
1 rotation = 100 litres
Pulse value of the modulator disc depending on the meter value
Type
Type
Type
A*
B*
C* *
11