How It Works - Eaton Metalux IB519008EN Suplemento De Las Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instruction Supplement – Luminaire with Integrated Sensor
Fixture Instructions
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new
construction or retrofit fixtures with the Integrated Sensor deliver automatic ON to an energy saving light level, while
ensuring lighting is turned OFF when the space is unoccupied.
The integral daylight sensor* reduces the need for special daylight zone planning. Each luminaire will automatically adjust the
light level based on reflected light beneath the sensor.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote
(Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant
(ASHRAE, IECC, T24) manual raise, lower, ON, OFF control.

How it works:

• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period
(default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver
light level. This adjustable light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF
default setting.
• Use the ISHH-01 Programming remote to customize the Occupied, Energy Save and Unoccupied light levels. Refer to the
Integrated Sensor programming guide for more information.
*Daylight sensing not available on some models.
100
(DO)
Daylight Level
0
Unoccupied
Occupied
INSTALLATION
Fixture Installation/Wiring
1.
Follow all installation and wiring instructions found on
the installation instructions for the luminaire.
2.
The integrated sensor controller is factory wired to the
luminaire, and does not require additional field wiring.
3.
Remove all luminaire and sensor protective covers prior
to using the integrated sensor system.
4.
Install all luminaires in the same area with the
integrated sensor in the same orientation, or as
indicated on the lighting plan.
5.
Refer to this guide for additional information regarding
the integrated sensor system.
2
EATON
IB519008EN
Energy Savings
Opportunities
(ES)
Energy Saver
Light Level
(DU)
Timeout Value
Unoccupied Level
Unoccupied
Installation Instruction Supplement
(DO)
Daylight Level
Occupied