Descargar Imprimir esta página

tau MEC 1000 Guía Para La Instalación página 18

Quadro de mandos para uno or dos motores 12v con encoder
Ocultar thumbs Ver también para MEC 1000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12V POWER SUPPLY
LOGIC WITH MICROPROCESSOR
ELECTRONIC ADJUSTMENT OF MOTOR TORQUE
END OF MANOEUVRE MOTOR DECELERATION
DOOR OPENING AND CLOSING DELAYS
WORK AND PAUSE TIME SELF-LEARNING FUNCTION
LED DISPLAY OF INPUT STATUSES
12V INPUT PROTECTION WITH FUSE
12V OUTPUT PROTECTION WITH FUSE
BUILT-IN BATTERY CHARGER CIRCUIT
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid breakdowns
of the line and false contacts;
-
do not re-use old pre-existing cables;
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the control
board.
CONNECTIONS TO THE TERMINAL BOARD
1-2
OPTIONAL: 12Vdc POWER SUPPLY supplementary voltage INPUT
+ Terminal 1, - Terminal 2. Contacts may only be used with the stabiliser card.
3-4
12Vdc, 7,2Ah DRY BATTERY input (FIAMM-12Vdc 7,2A batteries should be used).
This battery powers the system in the event of a blackout.
+ Terminal 3, - Terminal 4.
5-6
19Vdc OUTPUT, max. 20W.
For power supply to RECEIVERS and PHOTOCELLS, etc..
Protected by a 3,15A fuse (5x20).
+ Terminal 5, - Terminal 6.
7-8
M1 motor output 19Vdc, max. 50W.
Connect the motor with the electric lock. Delayed action during closing (this delay can be adjusted
with dip-switches 7A and 8A). Protected by a 10Ah fuse.
9-10
M2 motor outlet 19Vdc, max. 50W.
Connect the motor without the electric lock. Delayed action during opening. (Fixed delay).
Protected by a 10Ah fuse.
11-14 18Vdc output for FLASHING LIGHT, max. 15W.
+ Terminal 11, - Terminal 14 (Common=14).
12-14 INDICATOR LIGHT OUTPUT 12Vdc, max. 5W.
This lights up at the beginning of the opening phase until the gate is totally closed.
+ Terminal 12, - Terminal 14 (Common=14).
13-14 ELECTRIC LOCK OUTPUT 12Vdc, max. 15W.
This is active for 1 second before and 3 seconds after the close delay door (M1) starts opening.
DIP 2B can be used to select the courtesy light which remains on for approx. 3 minutes after the
manoeuvre has terminated. + Terminal 13, - Terminal 14 (Common=14).
15-17 PEDESTRIAN pushbutton input (Normally Open contact); this does exactly the same job as the
OPEN/CLOSE pushbutton; DIP 1A is used to control this function. (Common=17).
If the card is configured for 2 motors the pedestrian impulse completely opens the M1 motor door.
If it is configured for one motor the pedestrian open function can be programmed as preferred.