Scope of delivery
The scope of delivery for the appliance is shown on the
packaging. Check the contents for completeness when
unpacking. If any accessories are missing or in the
event of any shipping damage, please notify your deal-
er.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Safety devices
CAUTION
Missing or modified safety devices
Safety devices are provided for your own protection.
Never modify or bypass safety devices.
Dry run fuse
The device detects an absent or inadequate water sup-
ply. The pump switches off if water is not sucked and de-
livered within a certain time after switching on. This oc-
curs after 4 minutes in Manual mode and after 3 minutes
in Automatic mode. The "Suction side error" LED on the
display lights up.
Description of the unit
The maximum amount of equipment is described in
these operating instructions. Depending on the model
used, there are differences in the scope of delivery (see
packaging).
For the illustrations, refer to the graphics page
Illustration A
Connection adapter for pumps G1
1
Connection G1 (33.3 mm) suction line (inlet)
2
Filling nozzle
3
Pre-filter and integrated check valve
4
Cover
5
Cap, 2-way connection adapter
6
2-way connection adapter for pumps G1
7
Connection G1 (33.3 mm) pressure line (outlet)
8
ON/OFF switch
9
Cable storage and power supply cable with plug
10
Fault display
11
Rubber feet
12
LED "Error on suction side"
13
LED "Error on pressure side"
14
Cable clip
15
Opening assistance
16
We recommend using only original Kärcher suction hos-
es, filter components and hose connections. Using
components from other manufacturers can lead to mal-
functions when sucking the feed fluid, especially when
using bayonet connection systems.
Note
Even minor leaks lead to malfunctions.
Connect the suction hose
Note
We recommend using a suction hose with a backflow
stop. The backflow stop reduces the re-sucking time be-
cause it prevents the suction hose from draining after
water is dispensed. Do not install the backflow stop di-
rectly at the pump.
Note
We recommend using an additional pre-filter if sandy
water is to be delivered. Install the pre-filter between the
suction hose and pump.
For information on the backflow stop and pre-filter, see
chapter Accessories and spare parts.
1. Screw the connection adapter into the suction con-
nection of the pump (inlet) and tighten hand-tight.
Illustration B
2. Connect a vacuum-tight suction hose.
Connecting the pressure line
1. Screw the 2-way connection adapter into the pres-
sure connection of the pump (outlet) and tighten
hand-tight.
Illustration C
The 2-way connection adapter allows simultaneous
operation of 2 devices (e.g. washing machine and
sprinkler). It can be installed with both outlets at the
side or one outlet at the side and one outlet above.
Illustration D
2. Connect the pressure line.
3. Close the unused outlet with the cap supplied if only
one outlet is used.
1. Open and remove the filling nozzle cap, either man-
ually or using a screwdriver shaft (max. 8 mm diam-
eter).
2. Fill the pump via the filling nozzle, all the way to the
edge.
Illustration F
3. Screw the cap tightly onto the filling nozzle, either
manually or using a screwdriver shaft.
4. If present, open the stop valves in the pressure line
(see chapter Pressure balance and pressure relief).
English
Startup
Mobile use
Filling the pump
9