R&S HZ-14
1 Introduction
The near field EMC probes have been designed to measure localized magnetic and
electric fields from 9 kHz to over 1 GHz, for diagnosing and trouble shooting EMC
problems.
The two passive magnetic probes can be directly connected to a measuring receiver or
spectrum analyzer; with the active electric probe obtaining power via the RF cable
using the probe power adaptor.
The low noise preamplifier provided is used with the magnetic probes to increase their
sensitivity and because of their low power requirements, this and the electric probe can
be conveniently powered from the probe power outlet of most R&S Test Receivers and
Spectrum Analyzers.
The probe test jig can be used with a known signal source to verify the performance of
the two magnetic probes.
Fig. 1 Parts of R&S HZ-14
Operating Manual 1026.7767.12 - 01
Introduction
3