Orkli OKSOL-150 Manual De Instalación página 22

Ocultar thumbs Ver también para OKSOL-150:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
a)
The load range recommended for the system (l/day) 150 l/day at 45 ºC
b)
Details of long-term thermal efficiency and solar fraction calculated from the test for load volumes of 150 l/day for reference locations and
terms in the EN12976 standard:
System performance indicators only from solar or pre-heating on an annual basis
for a demand volume of:
Location:
Latitude :
Stockholm
(59,6ºN)
Würzburg
(49,5ºN)
Davos
(46,8ºN)
Athens
(38,0ºN)
c)
The total solar radiation on the collector plane during the protection test for excess temperature was 106.0 MJ/m 2, reaching a maximum
output temperature in the solar output of 69.3 º C.
When the system operates several days without water extraction until a solar radiation level accumulated on the collector plane greater than 106.0
MJ/m2, this can lead to overheating in the system. In this case the safety valve of the tank acts and draws water automatically protecting the system
INSTALLATION
8.
Recommendations and Warnings
The SL0-150 system should be installed by an authorised installer. All solar system components are supplied in the packaging in accordance with the
description provided in the table above.
Before installing the equipment, check:
a) The correct condition of all components.
b) Exact installation position and correct orientation.
In windy and snowy areas additional precautions should be adopted for such conditions. Contact the company for further information.
Recommendations
.
The assembly of the system needs a surface reduced for its assembly. The weight of the system should be taken into account (to see technical
register), since on inclined and sliding surfaces if the structure has not been attached beforehand
It can slide. It is therefore recommended to have a small crane available or place a stop.
.
Installation and layout:
a) System joints should be carried out bearing in mind that the ends of the pipe should not be dented and that they are aligned and flat with
the connection, completely joined and threaded without tension.
Connections
Ø CW Inlet
Ø CHW outlet
Ø Primary draining
Ø Secondary draining
Qd
[MJ]
8372
8029
9084
6239
User Manual - 22
Connections
1/2"
1/2"
1/2"
1/2"
QL
fsol
[MJ]
[%]
2624
31,3
3027
37,7
4006
44,1
4073
65,3
150 l/day
Qpar
[MJ]
---
---
---
---

Publicidad

Tabla de contenido
loading

Productos relacionados para Orkli OKSOL-150

Tabla de contenido