CA CHEMICAL DUAL FLOW
two arrow-buttons it is possible to set a lower level
(ECO) or a higher level (TURBO) of airflow.
TURBO mode makes protection more efficient than
the ECO mode, however in cold environment the
higher airflow could be uncomfortable.
The actual airflow level depends on the filter type
and state, with combined filters A2P3 the unit
supplies aprox. 135 l/min at ECO and aprox. 185
l/min at TURBO modes. In order to assure that the
airflow level is sufficient, perform the Air Flow Test –
chapt. 4..2.
Use flow indicator to check the airflow (pic. 5).
4.

Before use

4.1. Inspection before use
Each time before starting work check that :
all components are in good condition with no
visible damage (like holes, tears etc.) Replace
any damaged or worn parts. Carefully examine
the air hose, seals and the facepiece.
there is a good connection between the air hose
and the headpiece as well as the blower unit
there is sufficient air flow. (see chapt. 4.2.)
the air is supplied through the whole respiratory
system from the blower to the hood.
Charge the battery before the first use. (chapt. 6.2.)
4.2. Air Flow Test
CA BASIC 2000 DUAL FLOW
CA CHEMICAL DUAL FLOW
1. Disconnect the air hose from the hood.
2. Insert the indicator (the light
hose connector and keep the hose in vertical
position at about the eye level.
3. Switch the power unit on. The airflow is sufficient
if the indicator can be seen. If the indicator sinks
deeper into the hose connector and the airflow
corresponds to 120 l/min or less (see picture
supplement), it is necessary to charge the battery
or change the filter. If the problem still persists,
see chapter 7 for additional suggestions.
CA BASIC 2000 FLOW CONTROL
1. Disconnect the air hose from the hood.
2. Cover the disconnected end of the air hose with
your hand. The blower starts to run faster after
about 20 seconds, the audible alarm activates
and the LED diodes on the control panel start
blinking.
3. Release the hand . The blower speed should
decrease.
If the blower speed does not change, it is
Switch on the unit by
pressing the ON/OFF
button on the control
panel. There are two
arrow-buttons
on
the
switch board: ECO and
TURBO.
By using the
The
ball) into the air
necessary to check the unit as described in
chapter 7.
5.
Maintanence / Cleaning
It is recommended to clean the respiratory system
after each use. Also inspect all parts and replace
any which are damaged or worn.
Always clean the respiratory unit in a ventilated
room or outside.
settled on any parts of the unit.
Never use flammable cleaning liquids or abrasive
cleaners !
The outer surface of the blower unit can be
cleaned with a soft cloth wet slightly in a mild
solution of clean water and mild detergent. Dry it
properly afterwards.
Ensure that no water or detergents enter into the
blower unit !
The air hose itself, detached from the blower unit
and the headpiece, can be rinsed in clean water.
6.
Spare parts / Replacing spare parts
6.1. Filter
CA BASIC 2000
The respiratory power unit is equipped with a high
efficiency particle filter of class P R SL.
The filter must be regularly checked (see Air Flow
Test - chapter 4.2.) and replaced.
Make sure that the new filter is within its expiry
date, unused and not evidently damaged.
From the hygienic point of view
working time of a filter is 180 hours and should not
be exceeded.
It is prohibited to clean the filter by any procedure!
The particle filter can be used with a Pre-filter or
with an Odour filter which removes the unwanted
smell of harmless gases.
CHANGING THE FILTER OF CA BASIC 2000
see picture supplement no.1
pict. 1A :
Removing the filter cover: Face the silver filter cover
towards you. Put your index fingers and middle
fingers into the gaps between the body of the unit
and the filter cover on both sides.
pict. 1B :
Rest your thumbs on the top of the silver filter
cover. Then pull your fingers placed in the gaps
outwards lifting the filter cover off the unit.
ATTENTION! It is strictly forbidden to use any tools
to uncover the filter.
pict. 1C :
To remove the filter, take it out while rotating it.
Clean the unit from dust.
pict. 1D :
5
Be aware of harmful dust
the maximum