The DEL Ozone series generators work under vacuum. The Injector Manifold draws the ozone/air gas mixture out of the
ozone generator and mixes it into the water leaving behind some un-dissolved gas bubbles. These bubbles can affect
certain pool system components, so care must be taken when installing the ozone Injector Manifold.
The diagrams below cover common plumbing configurations. For other configurations or installation questions, please
call DEL Residential Pool & Spa Technical Support at 1 (800) 676-1335, or e-mail:
Pool Cleaners (i.e. Polaris 360): Always plumb the cleaner t-fitting before the DEL Ozone injector to prevent gas
from affecting the operation of the cleaner.
Salt Chlorinator: A Salt Chlorinator may be plumbed on either side of the DEL Ozone injector.
Chlorine Tab / Mineral Erosion Feeder: Always plumb the DEL Ozone injector after any erosion feeder to avoid
gas accumulating in the feeder.
In-Floor Cleaning System: The DEL Ozone Injector must be on a different pool return leg than any In-Floor
Cleaning system to avoid excess back pressure on the Injector. This will also prevent gas intrusion and high oxidizer
levels in zone valve and cleaner heads.
Water Features: Avoid plumbing the Injector Manifold into any leg with excessive back pressure such as those
going to fountains, restrictive wall fittings, etc.
Sanitizer
Heater
Actuator
Heater
To Spa
APPENDIX A
DEL Ozone Installation – Plumbing
Diagram 1: Pool Only
Pool
Cleaner
DEL
Ozone
Sanitizer
Injector
Manifold
DEL Ozone
Diagram 2: Pool/Spa Combo
In-Floor
Cleaner
Water
Features
DEL
Sanitizer
Ozone
Injector
Manifold
DEL Ozone
13
warrantysupport@delozone.com
Pool
Sanitizer
Pool
Sanitizer
4-1393-01_Rev.B