Master Valve and Station Connection
Using 18 -gauge (maximum 14 -gauge wire can be used), multi -strand, direct burial
irrigation valve connection cable is recommended. Select a cable that provides at least one
wire for each valve and one extra wire for the common connection.
IMPORTANT!
connectors on all splices.
Step 1 – To provide a valve common connection, splice one cable wire (generally the white
wire) and connect it to one solenoid lead from each of the valves.
Step 2 – Connect a separate wire to the remaining solenoid lead from each valve.
For reference, note the wire color code being used for each valve connection
and the associated watering station.
Step 3 – Remove the controller's lower
panel cover to access the master valve
and station terminals.
Step 4 – Route the wire cable into the controller
through the opening at the base of the
unit.
Step 5 – Secure the designated valve common
wire to the "
Step 6 – Secure the Master Valve to the "
terminal and the stations to their
corresponding terminals (
Step 7 – Reinstall the lower panel cover.
To prevent corrosion and possible short circuit, use waterproof wire
COM
" terminal.
S1, S2, S3, ...
MV
"
).
lawn
master
SENSOR
ON
OFF
PRG
RS1 RS2 AC1 AC2 COM MV
S1
S2
S3
S4
S5
S6
COM
S3
S2
S1
MV
COM